Anchoring steel for monoslab footing. Robert Olin 09-07-2009
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by jloomis on September 9, 2009, 9:27 am


Well that helps explain it better.
I know I have worked on State Jobs....that required epoxy coated rebar and
tie wire.....any cut was coated as well as wire.....
This rebar was in the large size family also....1" and even larger......
john
> wrote:
>>Hi Tom.
>>I have always wondered about this, and we always do put steel on concrete
>>blocking. not red brick......either.
>>there is a maintained 3" from earth contact in most plans.
>>Is the steel like a electrical wire that would transmit rust?
> Absolutely, rust will travel along steel (such as rebar) under paint
> and protective coatings. Because of the mechanics of how this rust
> spreads, it is very difficult to prevent, hence we limit the ability
> for water to contact steel.
>>I still have trouble visualizing rust following steel.
> Think of it this way. You get rust on the edge. Rust is very porous.
> Water travels in the rust, to new virgin steel, and rusts it. It is a
> continuous process, with the rust able to travel great distances by
> water being drawn in by capillary action.
> About the only thing that limits it (rust) is to use galvanized
> coatings such as hot-coat zinc. (Electroplate zinc is usually not
> thick enough to withstand long periods of time...) Not much rebar is
> zinc coated however.
> What makes things worse is some soils/sands are loaded with stuff that
> promotes rust, such as salt! (even inland, you can have corrosive
> sand, as the sand is often the result of ocean action over a long
> period of pre-history...)
>>Anyway, I do use concrete dobies.....
>>john



Posted by DanG on September 9, 2009, 7:06 pm


I have had to deal with several fairly major repairs where the
steel had rusted and the rust expanded enough to move the
concrete, break the concrete, or cause other damage. One involved
heaving a door mull enough to prevent the panic bars from
latching, unbond the terrazzo, and pressure the transom glass
overhead. Several others have involved shattering stair noses on
exterior concrete steps.

None of these involved rebar driven in the dirt, but rather
moisture through the concrete. I don't have any stories about
failed footing steel and have often wondered about the
requirement. Corps work is adamant about steel cover with no
ground contact.

--
______________________________
Keep the whole world singing . . . .
DanG (remove the sevens)
dgriff237@7cox.net



> Hi Tom.
> I have always wondered about this, and we always do put steel on
> concrete blocking. not red brick......either.
> there is a maintained 3" from earth contact in most plans.
> Is the steel like a electrical wire that would transmit rust?
> I still have trouble visualizing rust following steel.
> Anyway, I do use concrete dobies.....
> john
>> Rebar should NOT touch the ground or be driven into the ground
>> as a stake to support other bars. There is a reason that most
>> specs. call for a minimum clearance of 2-3 in. from the surface
>> of the concrete or earth contact. As John stated earlier, use
>> some concrete (NOT RED) bricks for chairs to suspend the horiz.
>> bars from the ground surface. The rust will travel to the bars
>> in the concrete over time and cause destruction of the footing
>> or slab. Surface rust or oxidation on reinforcing steel is
>> harmless if contained, however when the bars are subject to
>> severe rusting they expand and will ultimately cause the
>> concrete to fail.
>>> Anal. (although since it is not a bridge, a high rise, or an
>>> overpass, I do not see why not!)
>>> Most of the times I just use a dobe - concrete block that ties
>>> to steel. Or, make an angle out of a smaller
>>> rebar........right angle......say 2' x2' and rest it on the
>>> concrete 3" x 3" dobe and tie the steel to it.
>>> I cannot imagine the rust traveling from the ground........all
>>> the way up to possibly compromise the steel horizontal piece.
>>> john
>>>> Residencial code calles for one #5 bar in the center of a
>>>> mono slab footing or 2 #4 bars. Anyone know if it's ok to
>>>> drive a verticle piece of rebar into the ground to tie these
>>>> horizontal bars to, or are they so anal retentive that they
>>>> think the steel will rust into the concrete?
>>>> Thanks,
>>>> Bob
>>>> --
>>>> Robert Olin
>>>> Bob's Water & Septic LLC
>>>> jolin@whidbey.net
>>>> http://soilsandseptic.com/bobs.html
>



Posted by Tom Cular on September 10, 2009, 5:19 pm



> Hi Tom.
> I have always wondered about this, and we always do put steel on concrete
> blocking. not red brick......either.
> there is a maintained 3" from earth contact in most plans.
> Is the steel like a electrical wire that would transmit rust?
> I still have trouble visualizing rust following steel.
> Anyway, I do use concrete dobies.....
> john
>> Rebar should NOT touch the ground or be driven into the ground as a stake
>> to support other bars. There is a reason that most specs. call for a
>> minimum clearance of 2-3 in. from the surface of the concrete or earth
>> contact. As John stated earlier, use some concrete (NOT RED) bricks for
>> chairs to suspend the horiz. bars from the ground surface. The rust will
>> travel to the bars in the concrete over time and cause destruction of the
>> footing or slab. Surface rust or oxidation on reinforcing steel is
>> harmless if contained, however when the bars are subject to severe
>> rusting they expand and will ultimately cause the concrete to fail.
>>> Anal. (although since it is not a bridge, a high rise, or an overpass,
>>> I do not see why not!)
>>> Most of the times I just use a dobe - concrete block that ties to steel.
>>> Or, make an angle out of a smaller rebar........right angle......say 2'
>>> x2' and rest it on the concrete 3" x 3" dobe and tie the steel to it.
>>> I cannot imagine the rust traveling from the ground........all the way
>>> up to possibly compromise the steel horizontal piece.
>>> john
>>>> Residencial code calles for one #5 bar in the center of a mono slab
>>>> footing or 2 #4 bars. Anyone know if it's ok to drive a verticle
>>>> piece of rebar into the ground to tie these horizontal bars to, or are
>>>> they so anal retentive that they think the steel will rust into the
>>>> concrete?
>>>> Thanks,
>>>> Bob
>>>> --
>>>> Robert Olin
>>>> Bob's Water & Septic LLC
>>>> jolin@whidbey.net
>>>> http://soilsandseptic.com/bobs.html


John,

I think Peter and Dan have answered your question, so I won't go into the
tech. end of the whys and wherefores unless you want that info. If you do,
you know how to contact me. Hope the weather is nice in No. CA this time of
the year.


Posted by jloomis on September 10, 2009, 11:49 pm


Weather is beautiful.
I am going to stick to my usual method of placing rebar on dobies.
and keeping an earth contact away.....at least 3"
john
>> Hi Tom.
>> I have always wondered about this, and we always do put steel on concrete
>> blocking. not red brick......either.
>> there is a maintained 3" from earth contact in most plans.
>> Is the steel like a electrical wire that would transmit rust?
>> I still have trouble visualizing rust following steel.
>> Anyway, I do use concrete dobies.....
>> john
>>> Rebar should NOT touch the ground or be driven into the ground as a
>>> stake to support other bars. There is a reason that most specs. call for
>>> a minimum clearance of 2-3 in. from the surface of the concrete or earth
>>> contact. As John stated earlier, use some concrete (NOT RED) bricks for
>>> chairs to suspend the horiz. bars from the ground surface. The rust will
>>> travel to the bars in the concrete over time and cause destruction of
>>> the footing or slab. Surface rust or oxidation on reinforcing steel is
>>> harmless if contained, however when the bars are subject to severe
>>> rusting they expand and will ultimately cause the concrete to fail.
>>>> Anal. (although since it is not a bridge, a high rise, or an overpass,
>>>> I do not see why not!)
>>>> Most of the times I just use a dobe - concrete block that ties to
>>>> steel. Or, make an angle out of a smaller rebar........right
>>>> angle......say 2' x2' and rest it on the concrete 3" x 3" dobe and tie
>>>> the steel to it.
>>>> I cannot imagine the rust traveling from the ground........all the way
>>>> up to possibly compromise the steel horizontal piece.
>>>> john
>>>>> Residencial code calles for one #5 bar in the center of a mono slab
>>>>> footing or 2 #4 bars. Anyone know if it's ok to drive a verticle
>>>>> piece of rebar into the ground to tie these horizontal bars to, or are
>>>>> they so anal retentive that they think the steel will rust into the
>>>>> concrete?
>>>>> Thanks,
>>>>> Bob
>>>>> --
>>>>> Robert Olin
>>>>> Bob's Water & Septic LLC
>>>>> jolin@whidbey.net
>>>>> http://soilsandseptic.com/bobs.html
> John,
> I think Peter and Dan have answered your question, so I won't go into the
> tech. end of the whys and wherefores unless you want that info. If you
> do, you know how to contact me. Hope the weather is nice in No. CA this
> time of the year.



Posted by Robert Olin on September 11, 2009, 10:03 pm


Thanks guys. I don't want to do it twice so I'll will not be driving rebar
into the ground as stakes. I will need one #5 bar in the middle of the
footing. Thats about 10" above the ground. So, would you guys suspend it?
Thanks,
RO

--
Robert Olin
Bob's Water & Septic LLC
jolin@whidbey.net
http://soilsandseptic.com/bobs.html

> Weather is beautiful.
> I am going to stick to my usual method of placing rebar on dobies.
> and keeping an earth contact away.....at least 3"
> john
>>> Hi Tom.
>>> I have always wondered about this, and we always do put steel on
>>> concrete blocking. not red brick......either.
>>> there is a maintained 3" from earth contact in most plans.
>>> Is the steel like a electrical wire that would transmit rust?
>>> I still have trouble visualizing rust following steel.
>>> Anyway, I do use concrete dobies.....
>>> john
>>>> Rebar should NOT touch the ground or be driven into the ground as a
>>>> stake to support other bars. There is a reason that most specs. call
>>>> for a minimum clearance of 2-3 in. from the surface of the concrete or
>>>> earth contact. As John stated earlier, use some concrete (NOT RED)
>>>> bricks for chairs to suspend the horiz. bars from the ground surface.
>>>> The rust will travel to the bars in the concrete over time and cause
>>>> destruction of the footing or slab. Surface rust or oxidation on
>>>> reinforcing steel is harmless if contained, however when the bars are
>>>> subject to severe rusting they expand and will ultimately cause the
>>>> concrete to fail.
>>>>> Anal. (although since it is not a bridge, a high rise, or an
>>>>> overpass, I do not see why not!)
>>>>> Most of the times I just use a dobe - concrete block that ties to
>>>>> steel. Or, make an angle out of a smaller rebar........right
>>>>> angle......say 2' x2' and rest it on the concrete 3" x 3" dobe and tie
>>>>> the steel to it.
>>>>> I cannot imagine the rust traveling from the ground........all the way
>>>>> up to possibly compromise the steel horizontal piece.
>>>>> john
>>>>>> Residencial code calles for one #5 bar in the center of a mono slab
>>>>>> footing or 2 #4 bars. Anyone know if it's ok to drive a verticle
>>>>>> piece of rebar into the ground to tie these horizontal bars to, or
>>>>>> are they so anal retentive that they think the steel will rust into
>>>>>> the concrete?
>>>>>> Thanks,
>>>>>> Bob
>>>>>> --
>>>>>> Robert Olin
>>>>>> Bob's Water & Septic LLC
>>>>>> jolin@whidbey.net
>>>>>> http://soilsandseptic.com/bobs.html
>> John,
>> I think Peter and Dan have answered your question, so I won't go into the
>> tech. end of the whys and wherefores unless you want that info. If you
>> do, you know how to contact me. Hope the weather is nice in No. CA this
>> time of the year.
>



Page 2 of 3       < 1 2 3 > last >>
Similar ThreadsPosted
how to cross existing footing with new footing November 20, 2006, 12:24 am
anchoring bottom plate to beams August 22, 2007, 2:02 pm
Ledger to footing October 28, 2006, 12:27 pm
pouring a footing in soft clay April 24, 2007, 8:09 am
Driving Nails Inside 18" Footing July 25, 2009, 5:33 pm
Installing post footing in basement floor November 2, 2006, 10:11 am
Steel I Beams December 27, 2006, 12:33 pm
steel span May 17, 2007, 11:03 am
Steel Structure April 1, 2008, 11:25 pm
steel span July 24, 2008, 6:40 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap