Connecting new 3" sched40 to clay line

Building Construction - Building Construction Industry Discussions. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Connecting new 3" sched40 to clay line Mark G. 04-18-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Mark G. on April 18, 2007, 10:04 pm
Good evening.

I need to connect a new 3" schedule 40 line to an existing 3" clay tile
sewer line. Is there an easy way to connect the plastic pipe to the bell end
of an existing tile line? Or should I cut off the bell and use a Fernco
connector? The line is in a cramped area so cutting the tile will be
difficult.

Thanks
-Mark



Posted by Wayne Whitney on April 18, 2007, 11:52 pm

> I need to connect a new 3" schedule 40 line to an existing 3" clay
> tile sewer line. Is there an easy way to connect the plastic pipe to
> the bell end of an existing tile line?

I'm aware of two ways to do this, not sure which is better/easier:

(1) Measure the outer diameter of the clay bell and see if you can
find a rubber coupling that is close to the required OD. See
<http://www.missionrubber.com/Products/FlexSealCouplings.php>

(2) Fernco makes rubber donuts with a barbed profile for use in
connecting to hubs. The donut would fit over the 3" schedule 40 pipe
and would then wedge tightly into the 3" clay hub. See
<http://www.fernco.com/Donut.asp>

Cheers, Wayne


Posted by Mark G. on April 19, 2007, 10:45 pm
Thanks, Wayne. I believe the donut will work fine.



Posted by DAC on April 19, 2007, 7:14 am
> Good evening.
>
> I need to connect a new 3" schedule 40 line to an existing 3" clay tile
> sewer line. Is there an easy way to connect the plastic pipe to the bell end
> of an existing tile line? Or should I cut off the bell and use a Fernco
> connector? The line is in a cramped area so cutting the tile will be
> difficult.
>
> Thanks
> -Mark

What's the direction of flow? PVC -> Clay or Clay -> PVC? Wayne has
given you a couple of good options just make sure you choose the
fitting that will be the least disruptive to the flow.


Similar ThreadsPosted
Connecting a 2x8 joist to 2x4's January 7, 2008, 1:13 pm
FBI Official says, "No hard evidence connecting Bin Laden to 9/11" June 7, 2006, 2:16 am
Kankakee Clay Partition?? August 19, 2006, 1:57 am
Clay brick question August 25, 2007, 11:43 pm
pouring a footing in soft clay April 24, 2007, 8:09 am
concrete blocks v/s clay bricks October 19, 2007, 2:26 pm
FA Cottage Building manual in Cob Chalk Clay 1919 April 30, 2007, 6:51 pm
Pier Foundation for clay soil, high water table, 4 foot frost July 18, 2006, 7:25 pm
Zero Lot Line August 31, 2006, 5:47 pm
LPG supply line diameters December 24, 2006, 8:58 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap