Max.length of 3 meter unbuttresed double-brick wall ?

Building Construction - Building Construction Industry Discussions. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Max.length of 3 meter unbuttresed double-brick wall ? problems 11-15-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Michael Bulatovich on November 18, 2007, 5:39 pm

>
>>
>>> Here is S.Africa, where they had a burglary over a 1 meter high wall,
>>> they have highened the wall to 3 m. with old-used [but good quality]
>>> bricks which they had lying around.
>>>
>>> I have heard of free-standing walls collapsing and killing persons,
>>> eg. in a storm.
>>
>> It happens.
>>
>>> Apparently free-standing walls should have 'posts' built from eg.
>>> 4-bricks at specified intervals ?
>>
>> "Pilasters."
>>
>>> Since the government building inspection department is probably
>>> non-functional since the recent 'liberation take over', I'd like
>>> some international advice.
>>>
>>> The bricks are British imperial sized: 75x 110x 230 mm.
>>> The wall is double bricked, with 'cross-layed' at the top.
>>>
>>> [...]
>>
>> Another variable to consider is the straight length of the masonry
>> wall. Walls with jogs, spaced closely enough, buttress themselves.
>> (Our code here calls for intersecting walls or buttresses (pilasters)
>> at no more than 36x the wall thickness for non-loadbearing walls.)
>
> The UK codes have something similar - can't remember the ratio, 25 years
> since I last had to use it - but that code didn't have seismic
> requirements, or much in the way of wind-loading for free-standing, as I
> recall.
>
> Avoidance of pilasters would require some form of reinforced bond beam
> coping, maybe post-tensioned rods, foundation to coping at ?? spacing.
> Easier to do it in hollow masonry block. Keep the bricks for decorative
> paving. Or crush into pea-gravel for the same purpose :-)

This is already built and the OP is concerned about it...



Similar ThreadsPosted
Distance from transformer to service panel/meter October 28, 2006, 8:32 pm
max header span length January 27, 2007, 9:44 am
Wall Height August 20, 2006, 11:23 am
Retaining Wall March 16, 2007, 5:29 am
wall construction- April 11, 2008, 8:45 am
Re: wall construction- April 12, 2008, 12:55 am
Wall Decor April 29, 2008, 5:19 am
need help with retaining wall project!! September 19, 2006, 7:18 pm
Shear wall question October 12, 2006, 12:49 am
Is it a load-bearing wall? April 9, 2007, 11:40 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap