Posted by bmac on March 25, 2009, 6:08 pm
-------------------------------------
Question on the rafter connection at a structural ridge beam. Building is
in WA state (Pierce county) Cathedral ceilings with 2x12 rafters are
shown attached with simpson brackets to a 5 1/8 inch beam. (10/12 slope)
What is the best way to vent the ridge with such a thick ridge beam?
Would it be better to notch and place the rafters on top of the beam? Any
special connection to tie the rafters together? (is it still acceptable to
offset and lap the rafters?)
##-----------------------------------------------##
Delivered via http://www.thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.building.construction - 16057 messages and counting!
##-----------------------------------------------##
Posted by jloomis on March 25, 2009, 8:45 pm
I have notched the plywood roofing inbetween the rafters say, a 10" by 2 "
slot near the top inbetween the rafters, and then use a cora ridge strip
vent. The roof is shingled to the slot at the top. The strip vent is placed
at the lower edge of the slot on top of the shingles. I use Henry's or roof
seal on the bottom of the strip vent. This is nailed into the roof. then I
put a nice bead of Henry's or roof cement to the top of the strip vent and
place the next shingles on top of the strip vent. You have a 1" vent system
built into the roof at the top. they make a commercial plastic application
of this for the lower or bottom of the roof and that also could be used....
jloomis
show/hide quoted text
Posted by Cwatters on March 26, 2009, 5:32 am
> -------------------------------------
> Question on the rafter connection at a structural ridge beam. Building is
> in WA state (Pierce county) Cathedral ceilings with 2x12 rafters are
> shown attached with simpson brackets to a 5 1/8 inch beam. (10/12 slope)
> What is the best way to vent the ridge with such a thick ridge beam?
> Would it be better to notch and place the rafters on top of the beam? Any
> special connection to tie the rafters together? (is it still acceptable to
> offset and lap the rafters?)
Presumably the person who specified the beam is suitably qualified. Perhaps
best to ask them?
Similar ThreadsPosted
Spliced Ridge Beam October 10, 2006, 4:57 pm
12x16 shed roof ridge beam April 29, 2007, 10:16 pm
Timber truss connection - imperical to metric conversion July 21, 2009, 10:12 am
Rafter ties (metal straps) April 2, 2008, 1:57 pm
Rafters are separating from ridge board. November 22, 2006, 12:32 pm
Structural Engineering August 11, 2006, 4:08 pm
WTC 7 Structural Drawings Are Available March 26, 2007, 2:51 pm
structural fiberboard sheathing October 11, 2006, 9:02 am
Building leans- structural? November 11, 2006, 9:12 am
structural design studymetrial January 18, 2007, 11:25 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap