Home Page link

Switch-receptacle-fixture?

Building Construction - Building Construction Industry Discussions. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Switch-receptacle-fixture? AustinScoobee 11-29-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by AustinScoobee on November 29, 2006, 9:16 am
Hi everyone.
Wanted to know. Is there a way to wire, in order, Lightswitch--then
receptacle-then Light Fixture-?
We cannot open any walls or do any pulling of new wire, etc. It has
12-2 currently and the wife (who else) would like to change from
SW-Light-Light to SW - Receptacle-Light.

Can It be done? I dont thinkso off hand

Perhaps I should try... SW-- new wife--new wife's sis-?

Any help appreciated
Grr


Posted by Bob Morrison on November 29, 2006, 10:52 am
In a previous post AustinScoobee wrote...
> Hi everyone.
> Wanted to know. Is there a way to wire, in order, Lightswitch--then
> receptacle-then Light Fixture-?
> We cannot open any walls or do any pulling of new wire, etc. It has
> 12-2 currently and the wife (who else) would like to change from
> SW-Light-Light to SW - Receptacle-Light.
>
> Can It be done? I dont thinkso off hand
>
> Perhaps I should try... SW-- new wife--new wife's sis-?
>
> Any help appreciated
>

Depends on how the wire runs were made. If wire from the panel was run to
the first fixture box then a wire run to the switch it may be possible to
give you the SW-Receptacle-Light scenario.

You will have to turn off the switch, open the both fixture boxes, then
test for the presence of power in either of the boxes. If you have power
from the panel with the light switch off then you can wire a receptacle at
the box that has power.

On the other hand, if the power goes to the switch first, then the
fixtures I cannot think of a way to get to SW-Receptacle-Fixture without
fishing new wire.

--
Bob Morrison, PE, SE
R L Morrison Engineering Co
Structural & Civil Engineering
Poulsbo WA
bob at rlmorrisonengr dot com

Posted by DT on November 29, 2006, 12:09 pm
GordoSTI@gmail.com says...
>
>Hi everyone.
>Wanted to know. Is there a way to wire, in order, Lightswitch--then
>receptacle-then Light Fixture-?
>We cannot open any walls or do any pulling of new wire, etc. It has
>12-2 currently and the wife (who else) would like to change from
>SW-Light-Light to SW - Receptacle-Light.


Switch - Receptacle - Clapper - Light

--
Dennis


Posted by AustinScoobee on November 29, 2006, 2:25 pm
Thanks guys,
Telling my wife something is impractical and potentially dangerous, is
itself impractical and dangerous!
Thanks again
G


DT wrote:
> GordoSTI@gmail.com says...
> >
> >Hi everyone.
> >Wanted to know. Is there a way to wire, in order, Lightswitch--then
> >receptacle-then Light Fixture-?
> >We cannot open any walls or do any pulling of new wire, etc. It has
> >12-2 currently and the wife (who else) would like to change from
> >SW-Light-Light to SW - Receptacle-Light.
>
>
> Switch - Receptacle - Clapper - Light
>
> --
> Dennis



Contact Us | Privacy Policy