Posted by Bob Morrison on November 29, 2006, 10:52 am
In a previous post AustinScoobee wrote...
> Hi everyone.
> Wanted to know. Is there a way to wire, in order, Lightswitch--then
> receptacle-then Light Fixture-?
> We cannot open any walls or do any pulling of new wire, etc. It has
> 12-2 currently and the wife (who else) would like to change from
> SW-Light-Light to SW - Receptacle-Light.
>
> Can It be done? I dont thinkso off hand
>
> Perhaps I should try... SW-- new wife--new wife's sis-?
>
> Any help appreciated
>
Depends on how the wire runs were made. If wire from the panel was run to
the first fixture box then a wire run to the switch it may be possible to
give you the SW-Receptacle-Light scenario.
You will have to turn off the switch, open the both fixture boxes, then
test for the presence of power in either of the boxes. If you have power
from the panel with the light switch off then you can wire a receptacle at
the box that has power.
On the other hand, if the power goes to the switch first, then the
fixtures I cannot think of a way to get to SW-Receptacle-Fixture without
fishing new wire.
--
Bob Morrison, PE, SE
R L Morrison Engineering Co
Structural & Civil Engineering
Poulsbo WA
bob at rlmorrisonengr dot com
|