Posted by Joe on October 28, 2007, 12:58 pm

not sure if this is the right forum.

i'm planning on installing a "split" air conditioning
and heating unit in my attached 2 car garage (presently
insulated but unconditioned/unheated).

the side i'd like to mount the air handler/cooling/heating
unit on is a load bearing wall.

i might be worried over nothing, but since it is a load
bearing wall, would mounting that "split" part of the system
to the studs on that wall create any potential structural
problems. i don't see how it would, but thought i'd get
some opinions.

the other question is, in order to run the lines to that
split unit to the outside condensor/fan, we need to drill
openings in that load bearing wall. so if you go in between
the studs, it should be fine - right ? - how would a
reputable contractor seal up these holes after they've
run the lines ? (since the Tyvek, and CDX plyscore thats
under the vinyl siding is compromised by the hole)...is
it just a matter of injecting some sealing foam/compound?

thanks in advance for any responses.



Posted by DanG on October 28, 2007, 12:31 pm
You can't hurt anything about the wall unless you cut out framing
lumber. There really is nothing about the installation that even
fastens to the wall unless you create something for your own
purposes. There are two copper lines involved and probably power
and control wiring. It might be neater and cleaner to install one
sleeve though the wall between studs that is well caulked and
sealed. Send the lines and conduits through the sleeve - grow
foam with a little paint or caulk on the outside to seal the
lines.

--
______________________________
Keep the whole world singing . . . .
DanG (remove the sevens)
dgriff237@7cox.net



>
> not sure if this is the right forum.
>
> i'm planning on installing a "split" air conditioning
> and heating unit in my attached 2 car garage (presently
> insulated but unconditioned/unheated).
>
> the side i'd like to mount the air handler/cooling/heating
> unit on is a load bearing wall.
>
> i might be worried over nothing, but since it is a load
> bearing wall, would mounting that "split" part of the system
> to the studs on that wall create any potential structural
> problems. i don't see how it would, but thought i'd get
> some opinions.
>
> the other question is, in order to run the lines to that
> split unit to the outside condensor/fan, we need to drill
> openings in that load bearing wall. so if you go in between
> the studs, it should be fine - right ? - how would a
> reputable contractor seal up these holes after they've
> run the lines ? (since the Tyvek, and CDX plyscore thats
> under the vinyl siding is compromised by the hole)...is
> it just a matter of injecting some sealing foam/compound?
>
> thanks in advance for any responses.
>
>



Posted by Edwin Pawlowski on October 28, 2007, 4:16 pm

>
> i might be worried over nothing, but since it is a load
> bearing wall, would mounting that "split" part of the system
> to the studs on that wall create any potential structural
> problems. i don't see how it would, but thought i'd get
> some opinions.

Nope, it can take quite a bit.

>
>
it should be fine - right ? - how would a
> reputable contractor seal up these holes after they've
> run the lines ? (since the Tyvek, and CDX plyscore thats
> under the vinyl siding is compromised by the hole)...is
> it just a matter of injecting some sealing foam/compound?

Right. I'd use spray foam.



Posted by DT on October 28, 2007, 9:25 pm

>the other question is, in order to run the lines to that
>split unit to the outside condensor/fan, we need to drill
>openings in that load bearing wall. so if you go in between
>the studs, it should be fine - right ? - how would a
>reputable contractor seal up these holes after they've
>run the lines ?


The unit will come with a sleeve that goes through the wall. The one I
installed required a 2" hole

--
Dennis


Similar ThreadsPosted
Sliding glass door/brick install question December 1, 2006, 6:08 pm
Re: solar powered mini-split AC? August 3, 2006, 10:20 am
mini-split heat pumps May 12, 2007, 9:52 am
Advice needed regarding split entry expansion. November 27, 2006, 10:41 pm
Grass Paver Unit Cost August 12, 2006, 5:33 pm
Central air unit air flow noise problem November 28, 2006, 12:56 am
Which cheap refrigeration unit for fruit/wine pantry? October 8, 2006, 11:48 pm
where to buy prismatic rectangular wraparound flourescent lens 48" x 10" for older 2 t12 non-electronic ballast unit? October 30, 2007, 7:30 am
t&g osb install October 9, 2006, 9:09 am
Central Air Install July 31, 2006, 3:40 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap