vent stack and condensate SandM 05-13-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by SandM on May 13, 2007, 2:03 am
I have my 2nd floor HVAC in my attic. The condensate drains by PVC to the
basement. Recently, the line to drain the condensate has been leaking in the
soffit of the 2nd floor.

My question is can I have it drain into a vent stack? Or can I drain it into
a utility sink on the 2nd floor?

Steve



Posted by DanG on May 13, 2007, 12:59 am
It would be fine to have it go the utility sink or any drain line.
I believe code would want an air gap at the sink. The good thing
about the sink would be to visually verify flow and also to verify
efficient cooling.

--
______________________________
Keep the whole world singing . . . .
DanG (remove the sevens)
dgriff237@7cox.net



>I have my 2nd floor HVAC in my attic. The condensate drains by
>PVC to the
> basement. Recently, the line to drain the condensate has been
> leaking in the
> soffit of the 2nd floor.
>
> My question is can I have it drain into a vent stack? Or can I
> drain it into
> a utility sink on the 2nd floor?
>
> Steve
>
>



Posted by willshak on May 13, 2007, 9:46 am
SandM wrote:
> I have my 2nd floor HVAC in my attic. The condensate drains by PVC to the
> basement. Recently, the line to drain the condensate has been leaking in the
> soffit of the 2nd floor.
>
> My question is can I have it drain into a vent stack? Or can I drain it into
> a utility sink on the 2nd floor?
>
> Steve
>
>
>

Mine is draining into the vent stack passing through the attic. There is
a p-trap (or whatever it is called in a horizontal line) in the 1" pvc
drain line. Of course, the p-trap water evaporates between Summers, but
I have never smelled sewage in the attic.

--

Bill

Posted by Big_Jake on May 14, 2007, 12:33 am
> SandM wrote:
> > I have my 2nd floor HVAC in my attic. The condensate drains by PVC to the
> > basement. Recently, the line to drain the condensate has been leaking in the
> > soffit of the 2nd floor.
>
> > My question is can I have it drain into a vent stack? Or can I drain it into
> > a utility sink on the 2nd floor?
>
> > Steve
>
> Mine is draining into the vent stack passing through the attic. There is
> a p-trap (or whatever it is called in a horizontal line) in the 1" pvc
> drain line. Of course, the p-trap water evaporates between Summers, but
> I have never smelled sewage in the attic.
>
> --
>
> Bill

Your local building department might require a trap primer for such an
application. Here is an example;

http://www.plumbersurplus.com/Prod/PPP-PO-500-Oregon-1-Primer-Automatic-Trap-Primer-Valve/39615/Cat/776

JK


Posted by Dennis on May 14, 2007, 7:41 pm
The IRC requires that condensate be piped to "an approved place of
disposal". This would *not* allow it to connect to a sanitary waste or vent
system. It can drain to a indirect waste or just be piped out onto the
ground. It could also be connected to the downspouts I would imagine. But
legally, it can not connect to a vent pipe. (It's not just the smell or
sewer gas you need worry about, vents carry deadly bacteria as well.)


>I have my 2nd floor HVAC in my attic. The condensate drains by PVC to the
> basement. Recently, the line to drain the condensate has been leaking in
> the
> soffit of the 2nd floor.
>
> My question is can I have it drain into a vent stack? Or can I drain it
> into
> a utility sink on the 2nd floor?
>
> Steve
>
>



Similar ThreadsPosted
Re: Vent stack and furnace vent in same chase? November 15, 2006, 6:27 pm
Vent pipe question (pellet stove, Class A vent) September 3, 2007, 4:12 am
Range Hood Vent & Dryer Vent October 15, 2007, 7:39 pm
cutting into cast iron waste stack March 25, 2007, 8:00 pm
Vent or Faux Vent? November 30, 2006, 9:27 am
Vent or Faux Vent? December 1, 2006, 12:27 am
Should ALL bathroms have vent to outside? October 14, 2006, 1:01 pm
Water Heater Vent July 31, 2006, 8:49 am
Why a Heating and Air Vent in this location? December 23, 2006, 3:19 pm
Exhaust Vent on 1st Floor Bathroom June 29, 2007, 5:13 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap