Posted by Big_Jake on May 14, 2007, 12:33 am
> SandM wrote:
> > I have my 2nd floor HVAC in my attic. The condensate drains by PVC to the
> > basement. Recently, the line to drain the condensate has been leaking in the
> > soffit of the 2nd floor.
>
> > My question is can I have it drain into a vent stack? Or can I drain it into
> > a utility sink on the 2nd floor?
>
> > Steve
>
> Mine is draining into the vent stack passing through the attic. There is
> a p-trap (or whatever it is called in a horizontal line) in the 1" pvc
> drain line. Of course, the p-trap water evaporates between Summers, but
> I have never smelled sewage in the attic.
>
> --
>
> Bill
Your local building department might require a trap primer for such an
application. Here is an example;
http://www.plumbersurplus.com/Prod/PPP-PO-500-Oregon-1-Primer-Automatic-Trap-Primer-Valve/39615/Cat/776
JK
|