134a discharge pressures Stormin Mormon 09-19-2009
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Steve on September 20, 2009, 4:42 pm
show/hide quoted text
Not talking about a "subcooler", talking about *subcooling* where your
looking for the Delta T between LLP converted to temperature, and actual LLT
coming from the condenser. Normally for A/C and heat pumps, the Delta T
should be between 10 - 14F to insure a solid column of liquid refrigerant to
the TXV.
Posted by Stormin Mormon on September 20, 2009, 8:12 pm
The only time we change gas, is if the unit had R-12, and
then we use 416a. The older units are designed for R-12, and
the newer units come with R-134 in them. Not doing any
conversions.
Never worked on a two stage cooler.
--
Christopher A. Young
Learn more about Jesus
www.lds.org
Chris Why would you want change gas on first place
you put in a system what was design for
yes R-12 is expansive but customer is paying for it
so why would any one try to switch refrigerant?
And yes all new gases Refrigerants are working at
much higher pressures and higher discharge temperatures.
And for those of you that seems bring subcooler in
conversations the subcooler is always use in extreme
low temperatures and definitely not in AC systems
are in refrigerators if you find one system that does that
send or post name and model # of that unit I would
appreciate greatly.
in message
show/hide quoted text
Page 6 of 6       << first < 1 2 3
Similar ThreadsPosted
R-134a Price? August 28, 2006, 12:41 pm
Discharge temperature August 11, 2006, 11:39 pm
Differential Pressures and Duct Design 101... January 15, 2007, 7:35 pm
AC Register Discharge Temperature June 28, 2007, 12:09 pm
How far can you throttle down the discharge on a solar hot water circulating pump ? January 8, 2010, 9:49 am
What sort of external static duct pressures typically occur in Mobile/Mfd. Homes ? November 7, 2008, 7:09 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap