Subject Author Date
Alternative to freon? danmc68 08-17-2009
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Steve on August 20, 2009, 8:20 pm


> Does anyone have good leak detector?

Yes... http://www.inficon.com/download/en/TEK-Mate_brochure.pdf



Posted by Stormin Mormon on August 20, 2009, 9:52 pm


My D-Tek Tekmate is supposed to do HFC, but I havn't had
much success with it on 134a.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
.




> That is only because of different expansion and
> condensation ratios, nothing
> more. How do you compensate for the molecular leak down of
> R410A? Also, I have
> spent a great deal of time repairing the leaks in R410A
> systems installed by
> others. Fer Chists sake, Doesn't anyone teach these guys
> how to make a
> Military brazed Joint?

Does anyone have good leak detector?




Posted by Steve on August 21, 2009, 9:55 am


mine works great for R410a

> My D-Tek Tekmate is supposed to do HFC, but I havn't had
> much success with it on 134a.
> --
> Christopher A. Young
> Learn more about Jesus
> www.lds.org
> .
>> That is only because of different expansion and
>> condensation ratios, nothing
>> more. How do you compensate for the molecular leak down of
>> R410A? Also, I have
>> spent a great deal of time repairing the leaks in R410A
>> systems installed by
>> others. Fer Chists sake, Doesn't anyone teach these guys
>> how to make a
>> Military brazed Joint?
> Does anyone have good leak detector?
>



Posted by Don Ocean on August 21, 2009, 7:55 pm


Stormin Mormon wrote:
> My D-Tek Tekmate is supposed to do HFC, but I havn't had
> much success with it on 134a.        `

Change the tip filter.
>

Posted by Noon-Air on August 30, 2009, 1:38 pm



> Hey Jon
> Do not try to hose out new condensers the Finns are so tin
> that water pressure will bend the shit out of them,
> That is what the OEMs call progress. new AC system
> are design as throw way. No more fixing just install new.

The fins only bend if you try to wash them out with a fire hose or a high
powered preasure washer.


Page 2 of 3       < 1 2 3 > last >>
Similar ThreadsPosted
Small 'Alternative' Expansion Tank? October 17, 2007, 10:57 pm
Low on freon August 20, 2009, 9:57 pm
Can you still get freon? August 21, 2009, 8:18 am
fan versus low freon August 11, 2006, 4:36 pm
refrigerant and Freon August 18, 2009, 10:53 pm
Do units still use freon? August 21, 2009, 8:18 am