Condenser, Coil, Blower Sizing markgmoody 07-17-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by markgmoody on July 17, 2006, 3:04 pm
Folks,
Could you tell me, in general, how you feel about the following
combination of equipment. I know these are generalities but if you're
looking at Trane gear with these capacities, what if any are the
benefits/drawbacks?
3-ton condenser, SEER 13
3 1/2 ton coil
4 ton blower
80,000 BTU furnace
1500sq 2nd floor
Without being any kind of HVAC expert and without knowing any real
specifics about how you might go about optimally setting the TXV for
this configuration, my initial concern is:
1. blower load raising the avg temp of the coil and significantly
reducing latent heat removal capacity. (but will moving more air across
more coil surface area actually make up for the loss in latent heat
removal caused by higher coil temp?)
Posted by udarrell on July 17, 2006, 3:51 pm
markgmoody@gmail.com wrote:
show/hide quoted text
If the blower speed taps work out okay you can reduce the CFM to 350-CFM
per Ton, or 1050-CFM.
That will help to get a colder coil and increase run-time to reduce the
humidity.
If the equipment is sized right it will have adequate runtime to handle
the humidity and RM TH temp settings.
Get a RM TH with at least two degrees differential between the on/off
cycle for longer run-time cycles.
- udarrell - Darrell
--
Air Conditioning's Affordable Path to the "Human Comfort Zone Goal"
http://www.udarrell.com/air-conditioning-total-heat-enthalpy-latent-heat.html
For HVAC Techs:
http://www.udarrell.com/ac-trouble-shooting-superheat-subcooling.html
Similar ThreadsPosted
Help with Lennox coil sizing August 30, 2006, 8:50 pm
Amana 4 ton condenser blower motor July 11, 2007, 1:37 am
Blower Coil Freeze After Compressor Replacement? June 18, 2008, 12:15 pm
Condenser coil corosion July 31, 2009, 10:52 am
space-pak dunham bush blower coil needed asap November 13, 2007, 10:00 am
HVAC Sizing July 11, 2006, 7:27 am
Run time vs right-sizing December 7, 2006, 2:39 am
AC Sizing and compatability October 3, 2008, 8:20 pm
Need AC sizing help: Unit too small? July 20, 2006, 12:51 pm
Duct Sizing Question December 8, 2006, 7:00 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap