If you were Registered and logged in, you could reply and use other advanced thread options
|
Posted by on November 1, 2006, 10:39 am
Assuming that the dial on the fan/ limit switch is an accurate
measurement of temperature, what's the most efficient range of temps
that the dial should rest at when the blower is running and the burners
are on?
Thanks
|
|
Posted by Bubba on November 1, 2006, 4:33 pm
On 1 Nov 2006 07:39:24 -0800, 1jposi@gmail.com wrote:
>Assuming that the dial on the fan/ limit switch is an accurate
>measurement of temperature, what's the most efficient range of temps
>that the dial should rest at when the blower is running and the burners
>are on?
>Thanks
C'mon.........you dont really expect to save money on your utility
bill by adjusting the fan and limit control on your old ancient belt
driven clunker, do you?
Bubba
|
|
Posted by Steve Scott on November 1, 2006, 6:46 pm
It should rest where ever it needs to to maintain the manufacturer's
specified temperature rise.
On 1 Nov 2006 07:39:24 -0800, 1jposi@gmail.com wrote:
>Assuming that the dial on the fan/ limit switch is an accurate
>measurement of temperature, what's the most efficient range of temps
>that the dial should rest at when the blower is running and the burners
>are on?
>Thanks
--
My problem is drinking Coke in the
Pepsi generation
|
|
Posted by Bob_Loblaw on November 1, 2006, 7:06 pm
> It should rest where ever it needs to to maintain the manufacturer's
> specified temperature rise.
Air flow and output determines temperature rise, not a fan/limit.
If the fan settings did, you wouldn't need the limit, would you?
--
Respectfully, Bob
|
|
Posted by Steve Scott on November 1, 2006, 7:16 pm
My point exactly.
On Thu, 02 Nov 2006 00:06:38 GMT, "Bob_Loblaw"
>> It should rest where ever it needs to to maintain the manufacturer's
>> specified temperature rise.
>Air flow and output determines temperature rise, not a fan/limit.
>If the fan settings did, you wouldn't need the limit, would you?
--
My problem is drinking Coke in the
Pepsi generation
|
Page 1 of 4 1 2 3 > last >>
| Similar Threads | Posted | | Oil furnace fan limit switch | November 20, 2006, 10:24 pm |
| Question for limit switch-heating | November 9, 2008, 8:33 pm |
| Goodman Limit switch questions | April 21, 2009, 11:06 pm |
| Trane open high limit | January 31, 2007, 10:22 pm |
| Re: Trane open high limit | February 3, 2007, 8:59 am |
| Re: Trane open high limit | February 3, 2007, 10:23 pm |
| Re: Trane open high limit | February 6, 2007, 10:50 am |
| Re: Trane open high limit | February 7, 2007, 7:35 am |
| Re: Trane open high limit | February 2, 2007, 11:14 am |
| Re: Trane open high limit | February 2, 2007, 11:50 pm |
|
|
>measurement of temperature, what's the most efficient range of temps
>that the dial should rest at when the blower is running and the burners
>are on?
>Thanks