GAMA OR AGA Heat Exchanger Condemn Guidelines Bob Pietrangelo 01-22-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Bob Pietrangelo on January 22, 2008, 8:12 pm
I have been googling for a while and cant find the link for shutting down
furnaces with a heat exchanger crack. It's been here b4. Can anyone direct
me please

--
Bob Pietrangelo
bobp3@comcast.net (home)
bob@comfort-solution.biz (work)
www.comfort-solution.biz







Posted by Dr. Hardcrab on January 22, 2008, 8:43 pm

>I have been googling for a while and cant find the link for shutting down
>furnaces with a heat exchanger crack. It's been here b4. Can anyone
>direct me please

Not sure of a link, but we disconnect the t'stat wires, turn off the
emergency switch, and then we have a 2-part tag that says "CONDEMNED" with
space to explain why and a space for the customer to SIGN saying they were
told. We tag the furnace and take the original copy with us.

We still have customers call "a friend" to hook it back up, but at least we
are covered.....


Posted by Bob Pietrangelo on January 22, 2008, 8:54 pm
We do it similarly, but you will always find some hack that says you can
still use it. There was a directive or rec from GAMA or AGA or some other
governing body that said we shoul condemn and shut down if there is a crack.
Had one tonight that would blow out pilot when blower was running. It made
all kinda of dancing flames and pretty colors too!!!

--
Bob Pietrangelo
bobp3@comcast.net (home)
bob@comfort-solution.biz (work)
www.comfort-solution.biz





>
>>I have been googling for a while and cant find the link for shutting down
>>furnaces with a heat exchanger crack. It's been here b4. Can anyone
>>direct me please
>
> Not sure of a link, but we disconnect the t'stat wires, turn off the
> emergency switch, and then we have a 2-part tag that says "CONDEMNED" with
> space to explain why and a space for the customer to SIGN saying they were
> told. We tag the furnace and take the original copy with us.
>
> We still have customers call "a friend" to hook it back up, but at least
> we are covered.....



Similar ThreadsPosted
Forum Posting Guidelines October 16, 2006, 8:48 pm
Heat Exchanger October 16, 2007, 4:12 pm
Heat Exchanger question July 5, 2006, 11:17 am
heat exchanger noise March 3, 2007, 3:46 pm
soot in heat exchanger March 10, 2007, 10:01 am
Re: Cracked heat exchanger March 14, 2007, 7:00 pm
Re: Cracked Heat Exchanger, Soot Again - HELP!! April 12, 2006, 7:30 am
Goodman Manufacturing- fire box- heat exchanger April 10, 2007, 7:07 pm
Question about Cast Iron Heat Exchanger condensation? July 30, 2006, 1:29 pm
Large commercial hot water heat exchanger leaking November 9, 2007, 4:49 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap