Geothermal system and sinkholes

HVAC Discussions - Heating, ventilation and air conditioning. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Geothermal system and sinkholes bigdog 05-13-2009
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by bigdog on May 13, 2009, 2:42 pm
When I had my home built 8 years ago, I installed a geothermal heating/
cooling system. It is a vertical system with 3 wells although I am
unsure which are supply and which are return wells. I have had no
problem with the system itself but several years ago, I noticed a
sinkhole about a yard wide in the middle of my lawn. At first, I
didn't associate it with the geothermal system, but later I noticed
two other sinkholes at about where I believe the other two wells were.
In addition, the ground has sunk between the 3 wells and leading up to
the house. I have little doubt this is related to the geothermal
system but have no idea what is causing this. Is this a common problem
with geothermal systems and what can I do about it?

Posted by on May 13, 2009, 2:58 pm
On Wed, 13 May 2009 11:42:29 -0700 (PDT), bigdog

>When I had my home built 8 years ago, I installed a geothermal heating/
>cooling system. It is a vertical system with 3 wells although I am
>unsure which are supply and which are return wells.

        Then one where you pull water out is the supply. The own
where you put it back is the return

        You're welcome.


>I have had no
>problem with the system itself but several years ago, I noticed a
>sinkhole about a yard wide in the middle of my lawn. At first, I
>didn't associate it with the geothermal system, but later I noticed
>two other sinkholes at about where I believe the other two wells were.
>In addition, the ground has sunk between the 3 wells and leading up to
>the house. I have little doubt this is related to the geothermal
>system but have no idea what is causing this. Is this a common problem
>with geothermal systems and what can I do about it?

        RUN !!!!!

        Can you say 'foundation damage ????


--
Click here every day to feed an animal that needs you today !!!
www.theanimalrescuesite.com/

Paul ( pjm @ pobox . com ) - remove spaces to email me
'Some days, it's just not worth chewing through the restraints.'
'With sufficient thrust, pigs fly just fine.'
HVAC/R program for Palm PDA's
Free demo online at www.pmilligan.net/palm/
Free 'People finder' program now at www.pmilligan.net/finder.htm

Posted by Hermann on May 13, 2009, 7:05 pm
bigdog wrote:
> When I had my home built 8 years ago, I installed a geothermal heating/
> cooling system. It is a vertical system with 3 wells although I am
> unsure which are supply and which are return wells. I have had no
> problem with the system itself but several years ago, I noticed a
> sinkhole about a yard wide in the middle of my lawn. At first, I
> didn't associate it with the geothermal system, but later I noticed
> two other sinkholes at about where I believe the other two wells were.
> In addition, the ground has sunk between the 3 wells and leading up to
> the house. I have little doubt this is related to the geothermal
> system but have no idea what is causing this. Is this a common problem
> with geothermal systems and what can I do about it?

That Phenomenon is called the *China Syndrome*! Quite common in cracked
Nuclear reactors and piss poor installed Geothermal Units. There is a
bright side though. Many survived Chernobyl with only slightly massive
mutations etc.

Posted by geothermaljones on May 13, 2009, 10:08 pm
Sounds like your house is about 2-3000sf, if sized for cooling...if your
in Northern climes & it was sized for full heating then your 1500-1800sf.
The 3 vertical boreholes are probably vertical closed loops & I'd bet the
bores drove through an open cave, or a soft stone or peat layer.
I'd also bet your contractor didn't use a decent bentonite grout or even a
reasonable sludge pumped down the hole (via trembe tube) after the loops
were inserted. This grout/sludge insures the holes are sealed from surface
water drainage down & water swaps between the water tables a typical
vertical loops typically penetrate.
Here in MN we're not allowed to use vertical bore wells w/o bentonite
grout sealing the loops. I've got a 268' well for domestic & pump & dump
geothermal. when installed, I was told we shot through 5 or 6 different
water tables. The Grout keeps the rusty iron laden 35' water table from
contaminating the various lower water tables. We're also not allowed to
return the pumped water into a return well.
ECOLAB was fined a big chunk a while back for reinjection wells in it's
downtown St.Paul office building. We take fresh water pretty serious here in
the land of 10,000 lakes.
I'd bet your sinkholes are from the collapse of soft soil or cave layers
down below, or surface drainage washing down the tubes & dragging the slurry
to the bottom. In either case the install is suspect, but a few yards of
surface soil & grass seed should cure the problem. Although it may take a
generation or two to fully seal, when it finally stops, be assured your
loops will has a good a thermal transfer as is possible.

If your system is keeping your house comfortable, I'd have a couple
truckloads of soil spread about & live w/it.
If it's not working, call your installer...

Of course I might be mistaken.

goodluck
geothermaljones




> When I had my home built 8 years ago, I installed a geothermal heating/
> cooling system. It is a vertical system with 3 wells although I am
> unsure which are supply and which are return wells. I have had no
> problem with the system itself but several years ago, I noticed a
> sinkhole about a yard wide in the middle of my lawn. At first, I
> didn't associate it with the geothermal system, but later I noticed
> two other sinkholes at about where I believe the other two wells were.
> In addition, the ground has sunk between the 3 wells and leading up to
> the house. I have little doubt this is related to the geothermal
> system but have no idea what is causing this. Is this a common problem
> with geothermal systems and what can I do about it?



Posted by bigdog on May 14, 2009, 1:36 pm
wrote:
> =A0 =A0 Sounds like your house is about 2-3000sf, if sized for cooling...=
if your
> in Northern climes & it was sized for full heating then your 1500-1800sf.
> The 3 vertical boreholes are probably vertical closed loops & I'd bet the
> bores drove through an open cave, or a soft stone or peat layer.
> I'd also bet your contractor didn't use a decent bentonite grout or even =
a
> reasonable sludge pumped down the hole (via trembe tube) after the loops
> were inserted. This grout/sludge insures the holes are sealed from surfac=
e
> water drainage down & water swaps between the water tables a typical
> vertical loops typically penetrate.
> =A0 =A0 Here in MN we're not allowed to use vertical bore wells w/o bento=
nite
> grout sealing the loops. I've got a 268' well for domestic & pump & dump
> geothermal. when installed, I was told we shot through 5 or 6 different
> water tables. The Grout keeps the rusty iron laden 35' water table from
> contaminating the various lower water tables. We're also not allowed to
> return the pumped water into a return well.
> ECOLAB was fined a big chunk a while back for reinjection wells in it's
> downtown St.Paul office building. We take fresh water pretty serious here=
in
> the land of 10,000 lakes.
> =A0 =A0 I'd bet your sinkholes are from the collapse of soft soil or cave=
layers
> down below, or surface drainage washing down the tubes & dragging the slu=
rry
> to the bottom. In either case the install is suspect, but a few yards of
> surface soil & grass seed should cure the problem. Although it may take a
> generation or two to fully seal, when it finally stops, be assured your
> loops will has a good a thermal transfer as is possible.
> If your system is keeping your house comfortable, I'd have a couple
> truckloads of soil spread about & live w/it.
> If it's not working, call your installer...
> Of course I might be mistaken.
> =A0 =A0 =A0 =A0 goodluck
> =A0 =A0 =A0 =A0 geothermaljones
Thanks for the intelligent reply. The house is about 1760 sq. ft. with
a 1200 sq ft basement. The system itself is working fine. The supply
and return pipes enter the house about 4-5 feet below grade. Since
this home was built about an hour from my previous home, I was not
present when the wells were drilled, but having seen the ground after
they were covered over, it appeared to me that they dug a trench
diagonally from the front of the house to connect to the row of wells
about 25 feet from the house. Another trench connected the 3 wells. It
is along these two trenches that ground is sinking. I can understand
why the ground might be sinking around the head of the wells, but why
would it be sinking along these horizontal trenches. At the wells the
sink holes are about 2 feet wide and 1 to 2 feet deep. Along the
trenches ground has sunk about 6 to 12 inches. Grass already covers
the are of the sinking. If it is just a matter of bringing in some
dirt to level the ground, I'm OK with that but if this problem is
going to persist, I need to find a more permanent sollution. One idea
I had is to dig out the trenches again and put a layer of concrete
several feet below the turf but if the soil is going to continue to
sink beneath it, is that really going to fix the problem.
> > When I had my home built 8 years ago, I installed a geothermal heating/
> > cooling system. It is a vertical system with 3 wells although I am
> > unsure which are supply and which are return wells. I have had no
> > problem with the system itself but several years ago, I noticed a
> > sinkhole about a yard wide in the middle of my lawn. At first, I
> > didn't associate it with the geothermal system, but later I noticed
> > two other sinkholes at about where I believe the other two wells were.
> > In addition, the ground has sunk between the 3 wells and leading up to
> > the house. I have little doubt this is related to the geothermal
> > system but have no idea what is causing this. Is this a common problem
> > with geothermal systems and what can I do about it?- Hide quoted text -
> - Show quoted text -


Similar ThreadsPosted
Re: geothermal exchange help February 3, 2007, 10:56 am
Re: geothermal exchange help February 2, 2007, 10:38 pm
geothermal exchange help February 2, 2007, 4:13 pm
Geothermal and new vents October 30, 2007, 8:38 am
Geothermal Operating Costs September 8, 2006, 1:58 pm
GeoThermal unit in Ohio? August 7, 2008, 11:08 am
geothermal runs constantly November 24, 2008, 1:34 am
new Geothermal heating/AC considered May 7, 2009, 2:07 pm
Geothermal Water Pressure Problem July 15, 2006, 1:50 pm
Cost of geothermal heat pumps October 20, 2006, 9:12 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap