Posted by on January 5, 2008, 10:18 pm
I have a Munchkin 199M Boiler that started acting up recently. When
the boiler goes to light, it sonds like some one shooting skeet in my
basement. The first time this happened when I was standing next to the
boiler, I nearly jumped out of my skin. I think this backfiring also
caused the demise of the plastic induction fan impeller, which
fortunately still had 3 months left on the warranty, so I have the new
aluminum fan now installed. However, the detonation problem still
exists and the Service Techs and myself are stumped as to the cause.
Has anyone heard of this happeneng and know the cause? I've found
references to this in other posts on the net, but no one has yet
posted a definitive answer. Help!

Posted by geothermaljones on January 10, 2008, 7:59 pm
Your problem was restricted flow through the heat exchanger...
Fairly common if the system is filled with unconditioned water.
It results in crud build up, slowing flow & causing the water to boil &
flash to steam...
It does sound like a skeet range.
Glad you got it figured out.

good luck
geothermaljones
st.paul,mn


> I have a Munchkin 199M Boiler that started acting up recently. When
> the boiler goes to light, it sonds like some one shooting skeet in my
> basement. The first time this happened when I was standing next to the
> boiler, I nearly jumped out of my skin. I think this backfiring also
> caused the demise of the plastic induction fan impeller, which
> fortunately still had 3 months left on the warranty, so I have the new
> aluminum fan now installed. However, the detonation problem still
> exists and the Service Techs and myself are stumped as to the cause.
> Has anyone heard of this happeneng and know the cause? I've found
> references to this in other posts on the net, but no one has yet
> posted a definitive answer. Help!



Similar ThreadsPosted
Any boiler OWNER save money after converting to a high efficiency boiler? August 6, 2006, 11:25 am
Gas boiler October 14, 2007, 11:12 pm
Boiler Pressure June 2, 2007, 8:29 am
A boiler story December 8, 2007, 6:09 am
boiler selection December 27, 2007, 8:39 am
Boiler BTUs, how to calculate? July 3, 2006, 5:39 pm
tankless boiler efficiency? July 28, 2006, 4:17 pm
HELP: Old Hot water boiler needs replaced August 8, 2006, 4:49 pm
Oil Boiler runs...then shuts off. Help! October 30, 2006, 10:17 am
Re: Oil Boiler runs...then shuts off. Help October 31, 2006, 5:03 pm