Posted by Geoman on July 11, 2007, 8:31 am
NOTICE:

Just put in a CA storage refrigeration system.
Pulled the cap off the refrigerant line, prepared for brazing. Looked inside
the tubing and its plugged solid.

Found the factor put TWO plugs in the end! The other was shoved inside the
tubing.

So, is this a 'one time' incident or is this a potential major problem of
Cero (spelling) having a machine breakdown.

This could have really caused us major problems.
Be careful all those who are piping to check if you have a clear pipe.

Rich



Posted by The Freon Cowboy on July 11, 2007, 8:39 am
ive seen this before, as well .

while back , went on a call , new apartments , we put in the furnaces and gas
piping ,
first tenant in this unit , called cuz she was cold , furnace was underfiring,

checked fuel pressure , would build slowly until the valve would open and
then the bottom would fall out ,
suspected a bad regulator on the gas meter , called the gas co,
they come and check it , nothing wrong ,
unhook the gas pipe from the meter and then from inside the apartment
and let it have it with my co2 bottle
freakin sandwich bad pops out ,
guess someone ate their lunch and then put the bag inside the 1" pipe
and it got installed , without anyone catching it.
pressure test never would have caught this one
question remains , was someone being funny or malicious , or
was it just pure dumb luck , and someone stuffed it in there without realizing
what it would do ?



>NOTICE:


Posted by on July 11, 2007, 11:18 am

> ive seen this before, as well .
>
> while back , went on a call , new apartments , we put in the furnaces and
gas
> piping ,
> first tenant in this unit , called cuz she was cold , furnace was
underfiring,
>
> checked fuel pressure , would build slowly until the valve would open and
> then the bottom would fall out ,
> suspected a bad regulator on the gas meter , called the gas co,
> they come and check it , nothing wrong ,
> unhook the gas pipe from the meter and then from inside the apartment
> and let it have it with my co2 bottle
> freakin sandwich bad pops out ,
> guess someone ate their lunch and then put the bag inside the 1" pipe
> and it got installed , without anyone catching it.
> pressure test never would have caught this one
> question remains , was someone being funny or malicious , or
> was it just pure dumb luck , and someone stuffed it in there without
realizing
> what it would do ?


They stuck it in there to keep critters out, before it was hooked up?



Posted by The Freon Cowboy on July 11, 2007, 11:34 am
dont think so, it still had bread crumbs in it




Posted by on July 11, 2007, 12:06 pm

> dont think so, it still had bread crumbs in it

Oooops...



Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
two oil burner piping problem January 10, 2007, 9:20 pm
More stupid potential customer September 11, 2007, 6:11 pm
Has anyone used a Universal Potential Relay? Do they work? November 25, 2006, 6:41 pm
PEERLESS BOILER POTENTIAL FIRE December 28, 2007, 11:22 am
Discover How To Finally Unleash Your Computers True Potential! April 2, 2008, 12:21 am
Is Ranco having problems??? July 7, 2006, 10:26 am
Problems with air conditioner July 16, 2006, 10:52 pm
Problems with air conditioners, etc July 17, 2006, 11:41 am
Re: De dumidfication problems. September 28, 2006, 5:06 pm
Re: De dumidfication problems. October 11, 2006, 1:18 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap