Posted by lp13-30 on September 13, 2006, 11:43 am
I have a chance to get a new 1.5 ton Fujitsu mini split evap at a very
reasonable price. My plan is to add a txv to it and use a regular cond
unit which I already have. I had done that with a made in Thailand POS
that Goodman was selling. I just put a transformer and contactor in the
storeroom next to the breaker box and wired the system just like a
regular a/c, powering the contactor with the green circuit. It worked
fine, but it was only a 1 ton and I really need a 1.5, and was also
kinda dissapointed in the noise level of it. The Fujitsu is supposedly
230 volt, so I should be able to hook it up the same way. Anybody
familiar with this unit and have an comments about it-- good, bad,
average. No comments on my Frankenstein installation though :) Aaah WTF,
any comments welcome. Larry


Posted by r.bartlett on September 13, 2006, 5:07 pm

>I have a chance to get a new 1.5 ton Fujitsu mini split evap at a very
> reasonable price. My plan is to add a txv to it and use a regular cond
> unit which I already have. I had done that with a made in Thailand POS
> that Goodman was selling. I just put a transformer and contactor in the
> storeroom next to the breaker box and wired the system just like a
> regular a/c, powering the contactor with the green circuit. It worked
> fine, but it was only a 1 ton and I really need a 1.5, and was also
> kinda dissapointed in the noise level of it. The Fujitsu is supposedly
> 230 volt, so I should be able to hook it up the same way. Anybody
> familiar with this unit and have an comments about it-- good, bad,
> average. No comments on my Frankenstein installation though :) Aaah WTF,
> any comments welcome. Larry


Why bother ripping the gut's out in order to put a tev? Keep it simple by
using the existing exp device in the condenser and running the line sets as
per spec but not forgetting to insulate the small line. This makes for a far
cleaner installation and the outdoor works as it was designed too -i.e. with
a pre-expansion line.

I can see the American market adopting the pre-expansion idea in the
domestic market as it makes the install way easier and much quicker.It also
deskills the install as the need for all those silly charging charts is gone
when the condenser comes precharged for 30metres etc

I know for example that Daikin are looking very closely at this market and
would expect something along these lines very soon.

We use these a/c condensers for cellar coolers where the outdoor needs to be
very quiet -proper refrigeration ones are hellishly expensive- and we've
found that with a fridge evap sized correctly remembering to derate the
condenser for the lower temps they work really well.

Fujitsu are pretty good, Daikin and Mitsubishi are better but for your job
it should be fine. I don't know if you get inverter ones there yet but these
will not work in this set up so it needs to be the old fixed speed one.

Cheers

Richard



Posted by Stormin Mormon on September 14, 2006, 8:05 am
Not familiar with the unit. Have fun, and let us know how things work
out.

--

Christopher A. Young
You can't shout down a troll.
You have to starve them.
.

I have a chance to get a new 1.5 ton Fujitsu mini split evap at a very
reasonable price. My plan is to add a txv to it and use a regular cond
unit which I already have. I had done that with a made in Thailand POS
that Goodman was selling. I just put a transformer and contactor in
the
storeroom next to the breaker box and wired the system just like a
regular a/c, powering the contactor with the green circuit. It worked
fine, but it was only a 1 ton and I really need a 1.5, and was also
kinda dissapointed in the noise level of it. The Fujitsu is supposedly
230 volt, so I should be able to hook it up the same way. Anybody
familiar with this unit and have an comments about it-- good, bad,
average. No comments on my Frankenstein installation though :) Aaah
WTF,
any comments welcome. Larry



Posted by =?iso-8859-15?Q?Tekkie=AE?= on September 14, 2006, 9:04 pm
Stormin Mormon posted for all of us...

> Not familiar with the unit. Have fun, and let us know how things work
> out.
>
> --
>
> Christopher A. Young
>
The only "unit" you are familiar with is the bosses.
--
Tekkie "There's no such thing as a tool I don't need."

Similar ThreadsPosted
Mini split Wiring help please August 19, 2006, 11:40 am
Mini split issue October 18, 2006, 7:55 pm
Which Mini Split for Coastal Area August 19, 2006, 3:00 pm
Mini-split with auxiliary heat November 11, 2006, 11:00 pm
Mini-Split Universal remote November 13, 2006, 2:08 am
mini-split heat pumps August 7, 2008, 7:34 pm
Mini-split - heat pump in low ambient September 15, 2007, 12:53 am
Rough Ballpark Costs For Mini Split Installation in California? July 15, 2007, 6:07 am
Evap Specifications??? May 10, 2007, 9:31 pm
Evap Coils not all sweating May 29, 2007, 9:00 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap