Re: really quiet central AC/dehumidifier?

HVAC Discussions - Heating, ventilation and air conditioning. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Re: really quiet central AC/dehumidifier? Graven Water 06-25-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Graven Water on June 25, 2008, 11:51 am
"Stormin Mormon :)"

> Every central AC (or mini split) will reduce the humidity.

I need to reduce the humidity for allergy reasons, not just for
comfort. So it has to be at least 50% or below, maybe 40%, dust
mites die with 40% humidity. And I need to be able to reduce the
humidity when it's cool; yesterday it was 67F and 72% RH indoors :(

So I'm not sure if there are central AC units that can do this, to be
energy efficient they would have to have an option to either direct
inside air or outside air over the condenser. I could run a
central AC with a very low temperature threshold and run the heater
at the same time, but that would be wasteful.

I do have forced air gas heat, and it's good to know that the noisy
part of an AC can be outside, and it can use the blower in my
furnace.

I'm not sure though whether I have to have a separate whole-house
dehumidifier also.

It would probably be too hot to have JUST a whole-house dehumidifier.
It doesn't get horribly hot in here without AC or dehumidifier - I
got the roof ventilated and that helped to cool things down. But it
is humid here in the summer and if I were dehumidifying from 70% to
40% I suspect a whole house dehumidifier would be making the heat
inside a lot worse.

Laura


Posted by Noon-Air on June 25, 2008, 12:29 pm

> "Stormin Mormon :)"
>> Every central AC (or mini split) will reduce the humidity.
> I need to reduce the humidity for allergy reasons, not just for
> comfort. So it has to be at least 50% or below, maybe 40%, dust
> mites die with 40% humidity. And I need to be able to reduce the
> humidity when it's cool; yesterday it was 67F and 72% RH indoors :(

Get somebody who knows what they are doing to correct the refrigerant charge
in your cooling system, and do the calculations to insure that the system is
not oversized for your home. As far as the dust mites, mold and mildew
control, and to promote a healthy home, read the stuff written by Lew
Herriman on humidity control and mold avoidance.

> So I'm not sure if there are central AC units that can do this, to be
> energy efficient they would have to have an option to either direct
> inside air or outside air over the condenser. I could run a
> central AC with a very low temperature threshold and run the heater
> at the same time, but that would be wasteful.

A correctly sized, and installed cooling system will provide all the
humidity control you need without having to run at rediculously low temps.
The symptoms your discribing are telling me that you system is probably
oversized and not charged correctly... probably grossly overcharged.

> I do have forced air gas heat, and it's good to know that the noisy
> part of an AC can be outside, and it can use the blower in my
> furnace.

The new systems are so quiet that most folks refrigerators make more noise
than their refrigerators do.

> I'm not sure though whether I have to have a separate whole-house
> dehumidifier also.

Not with a correctly sized and properly installed cooling system.

> It would probably be too hot to have JUST a whole-house dehumidifier.
> It doesn't get horribly hot in here without AC or dehumidifier - I
> got the roof ventilated and that helped to cool things down. But it
> is humid here in the summer and if I were dehumidifying from 70% to
> 40% I suspect a whole house dehumidifier would be making the heat
> inside a lot worse.

I am in rural south Mississippi, and humidity is a real, year round issue.
Currently the ODT here is 90 with a heat index of 104


Posted by on June 25, 2008, 12:45 pm
wrote:

>> "Stormin Mormon :)"
>>> Every central AC (or mini split) will reduce the humidity.
>> I need to reduce the humidity for allergy reasons, not just for
>> comfort. So it has to be at least 50% or below, maybe 40%, dust
>> mites die with 40% humidity. And I need to be able to reduce the
>> humidity when it's cool; yesterday it was 67F and 72% RH indoors :(
>Get somebody who knows what they are doing to correct the refrigerant charge
>in your cooling system, and do the calculations to insure that the system is
>not oversized for your home. As far as the dust mites, mold and mildew
>control, and to promote a healthy home, read the stuff written by Lew
>Herriman on humidity control and mold avoidance.

        Harriman :-)


>The new systems are so quiet that most folks refrigerators make more noise
>than their refrigerators do.

        What he said ???? :-)



--
Click here every day to feed an animal that needs you today !!!
www.theanimalrescuesite.com/

Paul ( pjm @ pobox . com ) - remove spaces to email me
'Some days, it's just not worth chewing through the restraints.'
'With sufficient thrust, pigs fly just fine.'
HVAC/R program for Palm PDA's
Free demo online at www.pmilligan.net/palm/
Free 'People finder' program now at www.pmilligan.net/finder.htm

Posted by Noon-Air on June 25, 2008, 7:18 pm

> wrote:
>>> "Stormin Mormon :)"
>>>> Every central AC (or mini split) will reduce the humidity.
>>> I need to reduce the humidity for allergy reasons, not just for
>>> comfort. So it has to be at least 50% or below, maybe 40%, dust
>>> mites die with 40% humidity. And I need to be able to reduce the
>>> humidity when it's cool; yesterday it was 67F and 72% RH indoors :(
>>Get somebody who knows what they are doing to correct the refrigerant
>>charge
>>in your cooling system, and do the calculations to insure that the system
>>is
>>not oversized for your home. As far as the dust mites, mold and mildew
>>control, and to promote a healthy home, read the stuff written by Lew
>>Herriman on humidity control and mold avoidance.
> Harriman :-)
>>The new systems are so quiet that most folks refrigerators make more noise
>>than their condensers/heat pumps do.
> What he said ???? :-)

Sorry...my bad, that was before coffee

> --
> Click here every day to feed an animal that needs you today !!!
> www.theanimalrescuesite.com/
> Paul ( pjm @ pobox . com ) - remove spaces to email me
> 'Some days, it's just not worth chewing through the restraints.'
> 'With sufficient thrust, pigs fly just fine.'
> HVAC/R program for Palm PDA's
> Free demo online at www.pmilligan.net/palm/
> Free 'People finder' program now at www.pmilligan.net/finder.htm


Posted by Stormin Mormon on June 25, 2008, 10:00 pm
Join the Mormons. Travel to far away places, teach the gospel, and no coffee
needed.

--
Christopher A. Young
Learn more about Jesus
www.lds.org
.



>>The new systems are so quiet that most folks refrigerators make more noise
>>than their condensers/heat pumps do.
> What he said ???? :-)

Sorry...my bad, that was before coffee




Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
really quiet central AC/dehumidifier? June 24, 2008, 10:23 am
Re: really quiet central AC/dehumidifier? June 25, 2008, 8:04 am
Re: really quiet central AC/dehumidifier? June 25, 2008, 8:58 am
Re: really quiet central AC/dehumidifier? June 25, 2008, 10:36 am
Re: really quiet central AC/dehumidifier? June 25, 2008, 11:15 am
Re: really quiet central AC/dehumidifier? June 25, 2008, 12:00 pm
Re: really quiet central AC/dehumidifier? June 25, 2008, 3:46 pm
Re: really quiet central AC/dehumidifier? June 26, 2008, 7:49 am
Re: really quiet central AC/dehumidifier? June 26, 2008, 8:24 am
Re: really quiet central AC/dehumidifier? June 26, 2008, 3:14 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap