Posted by smerby on April 15, 2007, 10:41 am
I have a Norton 271H HSI that I need to replace on my boiler. I cannot
find a perfect match between ceramic block style, connector, and lead
wire length. My current specs are connector D, and 5 1/4 inch lead
wire length. The cermaic style is opposite the D style with the
indented ridge on the right side instead of the left. Does anyone have
any suggestions.

Thanks a lot
Bob


Posted by Noon-Air on April 15, 2007, 11:24 am
Call the dealer for the particular brand of boiler that you have. They
should have a couple of them in the truck.

>I have a Norton 271H HSI that I need to replace on my boiler. I cannot
> find a perfect match between ceramic block style, connector, and lead
> wire length. My current specs are connector D, and 5 1/4 inch lead
> wire length. The cermaic style is opposite the D style with the
> indented ridge on the right side instead of the left. Does anyone have
> any suggestions.
>
> Thanks a lot
> Bob
>



Posted by on April 15, 2007, 1:42 pm

> I have a Norton 271H HSI that I need to replace on my boiler. I cannot
> find a perfect match between ceramic block style, connector, and lead
> wire length. My current specs are connector D, and 5 1/4 inch lead
> wire length. The cermaic style is opposite the D style with the
> indented ridge on the right side instead of the left. Does anyone have
> any suggestions.
>
> Thanks a lot
> Bob
>


OEM



Posted by Bubba on April 15, 2007, 2:16 pm
wrote:

>I have a Norton 271H HSI that I need to replace on my boiler. I cannot
>find a perfect match between ceramic block style, connector, and lead
>wire length. My current specs are connector D, and 5 1/4 inch lead
>wire length. The cermaic style is opposite the D style with the
>indented ridge on the right side instead of the left. Does anyone have
>any suggestions.
>
>Thanks a lot
>Bob

Call Stormy. Im sure his boss can get it for you.
Bubba

Posted by danger on April 15, 2007, 4:10 pm
http://www.patriot-supply.com/products/showitem.cfm/46176

There you go, $25 same day delivery.

Measure it's resistance cold, should read 50-95 Ohms, then measure the amperage
as it
lights, should be around 3.5A. If it lights without a delay then all is well.

How old was the existing HSI? Make sure there is no rusted out HSI shield.
Maybe
condensation from the boiler is dripping onto the HSI.


-Canadian Heat


--
--------------------------------- --- -- -
Posted with NewsLeecher v3.8 Final
Web @ http://www.newsleecher.com/?usenet
------------------- ----- ---- -- -


Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Replacement for Ice Cap RSK 16 x 36 July 26, 2006, 3:01 pm
Best replacement for R12 August 17, 2008, 5:33 pm
coil replacement July 29, 2006, 9:34 am
Rheem Replacement? July 31, 2006, 9:02 pm
replacement thermostat March 19, 2007, 7:54 am
Duct Replacement April 1, 2007, 2:23 am
line set replacement help May 31, 2007, 10:51 pm
Drop in replacement for R22 October 19, 2007, 1:52 pm
S/S Replacement Chimney Cost? August 20, 2006, 1:48 pm
replacement condenser question June 11, 2007, 8:04 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap