Posted by Zyp on December 6, 2007, 1:59 am
Tekkie® wrote:
> Noon-Air posted for all of us...
>
>> Just in case anybody else runs across this problem(the OP contacted
>> me privately), the old board part number is 47-21517-22
>> The new revised board part number is 47-21517-92. The RPNE units are
>> new enough so that they should be under warranty.
>> This board is also used on most of the other newer (3 or so years
>> old) *JAZ* series heat pumps.
>>
>> The JEZ series have a mother board in them and use a different
>> "daughter" DDC board.
>>
>>
>>>
>>>> I'm curious if anyone else has noticed that Rheem RPNE HP's are
>>>> sensitive to power glitches. I've observed that they won't come on
>>>> after an outage without shorting the Ranco defrost board test pins.
>>>> Once a self test is initiated they'll run perfect until the next
>>>> power outage. Simply cycling power doesn't seem enough.
>>>>
>>>> I'm curious if the control board is sensitive to the sequence of a
>>>> power restore. Does it want LV or HV first.
>>>>
>>>> I'm just curious what others have observed?
>>>
>>> Which Ranco board?? The one with the self diagnostics on it?? they
>>> had a problem with that one, its under warranty and you should be
>>> able to have you local Rheem dealer warranty the board for you.
>>> With the complete model number and serial number from the heat
>>> pump, I can give you the correct part number for the new board.
>>>
>>>
>>
>>
>>
> Is there a JIZZ series? I betcha it's comin fast! I'm sorry...
> --
> Tekkie Don't bother to thank me, I do this as a public service.
Doesn't the JIZZ series come from the RHEEM?
--
Zyp
|