Posted by tex.dude on July 29, 2006, 9:34 am
I just invested some in a new A/C system replacing the air handler
(inside) and the condenser (outside). The company that did the work
said that I didn't need a new coil but after a few nites i'm starting
to wonder if that is true because it doesn't seem that the new unit is
getting as cold as the old unit. There is more air coming thru the new
unit (special thanks goes to the whistling sound that is coming thru
the return vent) and i'm wondering if the old coil is big enough to
handle the addtl airflow?
Posted by Moe Jones on July 29, 2006, 10:07 am
Allot of the times, in the long run, it the best time to replace the
evaporator coil when you replace the air handler. Most of the time the coil
& air handler is the same age.
The whistling sound may be a air leak in the return.
--
Moe Jones
HVAC Service Technician
Energy Equalizers Inc.
Houston, Texas
show/hide quoted text
Posted by ~^Johnny^~ on August 3, 2006, 10:14 pm
wrote:
show/hide quoted text
I had that problem with the carburetor on my Edsel.
An overhaul kit solved the problem.
It was only a gas kit. But it sucked, until
I got it fixed.
Wanna buy a Pinto? How about a Colt?
No? How about a Probe?
Make me an offer I can't refuse!
--
-john
wide-open at throttle dot info
Posted by ~^Johnny^~ on August 3, 2006, 10:56 pm
wrote:
show/hide quoted text
No shit, Sherlock!
--
-john
wide-open at throttle dot info
Posted by udarrell on July 29, 2006, 12:13 pm
tex.dude@yahoo.com wrote:
show/hide quoted text
They should have matched the condenser with a new matched A-Coil, or at
least a TXV refrigerant control, and a transition into the air intake
area of the A-Coil.
There should not be any whistling noises.
The return is also probably not sized big enough, with enough area for
the filter to get the air velocity down to 300-FPM.
If there is way too much airflow and it was charged with refrigerant
when the conditioned space was excessively hot, read the linked page below!
That could be the capacity problem!(?) It may be seriously overcharged,
airflow maybe within perimeters' when charge is adjusted at normal room
temperatures.(?)
http://www.udarrell.com/airconditioning-excessive-airflow.html
- udarrell
--
Air Conditioning's Affordable Path to the "Human Comfort Zone Goal"
http://www.udarrell.com/air-conditioning-total-heat-enthalpy-latent-heat.html
Techs:
http://www.udarrell.com/ac-trouble-shooting-superheat-subcooling.html
Similar ThreadsPosted
Blower Coil Freeze After Compressor Replacement? June 18, 2008, 12:15 pm
Replacement cost for an American Standard (Trane ?) coil September 10, 2006, 12:50 pm
Replacement for Ice Cap RSK 16 x 36 July 26, 2006, 3:01 pm
Replacement HSI April 15, 2007, 10:41 am
Best replacement for R12 August 17, 2008, 5:33 pm
Rheem Replacement? July 31, 2006, 9:02 pm
replacement thermostat March 19, 2007, 7:54 am
Duct Replacement April 1, 2007, 2:23 am
line set replacement help May 31, 2007, 10:51 pm
Drop in replacement for R22 October 19, 2007, 1:52 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap