commercial carbon monoxide detectors... daytona 09-12-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by daytona on September 12, 2006, 8:21 pm
What a bitch trying to search for a commercial type CO detector. I need one
to replace a unit that is defective in a Condo Building we maintain. The two
that run the garage fans are made in Israel and con not locate any info on
them. Does anyone have any name brands that might come to mind?
Thanks
JB



Posted by on September 12, 2006, 11:12 pm

>What a bitch trying to search for a commercial type CO detector. I need one
>to replace a unit that is defective in a Condo Building we maintain. The two
>that run the garage fans are made in Israel and con not locate any info on
>them. Does anyone have any name brands that might come to mind?
>Thanks
>JB
>

a few years ago I had a job installing two such systems in an
underground parking garage. I used detectors made by these guys to
control the fans:

http://www.macurco.com/codetectors.html

very easy to setup & calibrate....

Posted by on September 12, 2006, 11:18 pm
gofish@gonefishin.net wrote:

>
>>What a bitch trying to search for a commercial type CO detector. I need one
>>to replace a unit that is defective in a Condo Building we maintain. The two
>>that run the garage fans are made in Israel and con not locate any info on
>>them. Does anyone have any name brands that might come to mind?
>>Thanks
>>JB
>>
>
>a few years ago I had a job installing two such systems in an
>underground parking garage. I used detectors made by these guys to
>control the fans:
>
>http://www.macurco.com/codetectors.html
>
>very easy to setup & calibrate....


this is the one I used....

http://www.macurco.com/shcm21a.pdf

Posted by daytona on September 13, 2006, 7:00 am
Thanks go fish. I did locate that site, but will look into the model you
used. The other model I was looking at, seemed to use a controller board
with remote sensors. The two that are in the building now are 120v and are
in parallel to bring in a 120v contactor coil for the fans. The Macurco has
24v circuits. I guess the Assoc Board is going to have to dig deeper to get
the circuits rewired and isolated or change both. Guess we were just looking
for a replacement way out....but as life has it, it's no that simple anymore
JB

> gofish@gonefishin.net wrote:
>
>>
>>>What a bitch trying to search for a commercial type CO detector. I need
>>>one
>>>to replace a unit that is defective in a Condo Building we maintain. The
>>>two
>>>that run the garage fans are made in Israel and con not locate any info
>>>on
>>>them. Does anyone have any name brands that might come to mind?
>>>Thanks
>>>JB
>>>
>>
>>a few years ago I had a job installing two such systems in an
>>underground parking garage. I used detectors made by these guys to
>>control the fans:
>>
>>http://www.macurco.com/codetectors.html
>>
>>very easy to setup & calibrate....
>
>
> this is the one I used....
>
> http://www.macurco.com/shcm21a.pdf



Posted by on September 13, 2006, 10:39 am
"daytona" wrote:

>The two that are in the building now are 120v and are
>in parallel to bring in a 120v contactor coil for the fans. The Macurco has
>24v circuits

my situation was that the existing 3 phase fans were controlled by a
fused disconnect, like a Square D 321 NRB. So they were on 24/7.

I installed a 12x12 j-box next to the disco and wired in a 208/24 xfmr
and 3 pole contactor which was controlled by the CO sensor. So yeah,
a few xtra bux but then again, they got a top shelf sensor.

Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Moisture and Carbon Monoxide May 20, 2007, 7:36 pm
Leak Detectors July 15, 2007, 11:38 pm
H-10 leak detectors. Who can fix mine? May 9, 2008, 11:23 am
410A leak detectors June 3, 2008, 11:34 am
need help with a commercial ice machine January 2, 2008, 12:11 pm
Commercial hood and furnace July 7, 2006, 3:54 am
question for the commercial guys January 9, 2007, 12:37 am
What are commercial hvac systems like? April 1, 2007, 4:03 am
Is a rooftop commercial HVAC R22 still usable? May 23, 2007, 1:50 pm
Hardware Requirements for Commercial AC unit. May 24, 2007, 10:18 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap