Posted by Rich Nolan on July 29, 2008, 11:51 pm


I have a heat pump installed in my Virginia (Norfolk) house with a gas
pack... there is a variable setting for when to run the gas for heat (colder
weather) or when to run the heat pump for heat (milder weather)... what temp
should this be set at to be most efficient?




Posted by KJPRO on July 30, 2008, 12:13 am



>I have a heat pump installed in my Virginia (Norfolk) house with a gas
> pack... there is a variable setting for when to run the gas for heat
> (colder
> weather) or when to run the heat pump for heat (milder weather)... what
> temp
> should this be set at to be most efficient?


Nobody here can tell you without a lot of data... that data includes...
Electrical cost per KW
Fuel cost per CF or gallon.
Homes requirements compared to HP's capacity, BP (balance point)
COP (co-efficiency of preformance) of the HP at various OAT (outdoor ambient
temp)

Normally for my area, that equals the lowest possible setting where the HP
can still maintain the indoor temp.



Posted by Oztech on July 30, 2008, 8:41 am



>I have a heat pump installed in my Virginia (Norfolk) house with a gas
> pack... there is a variable setting for when to run the gas for heat
> (colder
> weather) or when to run the heat pump for heat (milder weather)... what
> temp
> should this be set at to be most efficient?
Hit the 'off' button. thats the most efficient setting.

Paul



Posted by geothermaljones on July 31, 2008, 12:10 am


Start at 32dF, if it keeps the house warm step it down a couple.
If that works step down a couple more,
Repeat...
If it doesn't work step up...
In our area 26dF is recommended, but with a proper setup & a fossil fuel kit
many are running them down below 15dF
HP doesn't cover the full load, but it stretches the HP output to minimize
the gas consumption.

goodluck
geothermaljones
st.paul,mn.



>I have a heat pump installed in my Virginia (Norfolk) house with a gas
> pack... there is a variable setting for when to run the gas for heat
> (colder
> weather) or when to run the heat pump for heat (milder weather)... what
> temp
> should this be set at to be most efficient?
>



Similar ThreadsPosted
Electric efficiency just went down... March 10, 2007, 11:01 pm
fan coil efficiency June 6, 2007, 3:42 am
tankless boiler efficiency? July 28, 2006, 4:17 pm
High efficiency boiler question? August 4, 2006, 5:41 pm
Re: Air return duct to outside - effect on efficiency? January 8, 2008, 9:14 am
Re: Air return duct to outside - effect on efficiency? January 10, 2008, 8:20 pm
Possible myth about high efficiency boilers =$$$ to sellers? August 7, 2006, 5:07 pm
high efficiency boiler recommendations needed August 11, 2006, 12:12 am
Question about high efficiency Furnace Exhaust January 16, 2007, 10:48 pm
High Efficiency gas furnace - return air temperature January 19, 2007, 12:12 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap