Thanks all for your responses;
The circulating pump runs at all times, the local thermostat/valve
allowing the hot water to route through the rads along the outside
walls. The abient air temp may still be high (higher than the normal
freeze protection temp) while the rad next to the wall experiences
much colder temps and is thus subject to freezing.

These are all individual apartments, with the occupants setting their
own temperatures, perhaps even leaving them off in the winter if heat
from other units is enough, and/or leaving windows open in the winter
(freezing air dropping down over the window sill onto the pipes)
setting the stage for burst pipes.

The thermostat needs to compensate for the poor actions of tenants.

Posted by Bubba on February 27, 2008, 7:29 am
On Tue, 26 Feb 2008 20:45:41 -0800 (PST), bbortnick@gmail.com wrote:

>Thanks all for your responses;
>The circulating pump runs at all times, the local thermostat/valve
>allowing the hot water to route through the rads along the outside
>walls. The abient air temp may still be high (higher than the normal
>freeze protection temp) while the rad next to the wall experiences
>much colder temps and is thus subject to freezing.
>These are all individual apartments, with the occupants setting their
>own temperatures, perhaps even leaving them off in the winter if heat
>from other units is enough, and/or leaving windows open in the winter
>(freezing air dropping down over the window sill onto the pipes)
>setting the stage for burst pipes.
>The thermostat needs to compensate for the poor actions of tenants.

NO! The apartment owner needs to be compensated for the stupid actions
of the tennants. If the tennants had to pay to repair frozen pipes
because of their stupid actions Id bet there would be a whole lot less
repairs of that type.
Bubba

Similar ThreadsPosted
Follow up on 220 VAC condenser fan at 110 VAC October 25, 2006, 4:17 pm
Info July 29, 2007, 5:55 pm
Info August 1, 2007, 5:03 am
Air conditioners info June 6, 2007, 9:15 am
Looking for furnace info December 15, 2007, 11:30 am
Carrier info nuts.... May 10, 2007, 6:55 pm
Refrigerant Capacity Info Request October 17, 2006, 11:57 am
Duct work sizing info. February 6, 2007, 4:59 pm
Need info on Honeywell L7224U boiler control May 13, 2007, 2:18 pm
Info needed on older Carrier 40AQ series February 10, 2009, 4:19 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap