two oil burner piping problem oilman4627 01-10-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by on January 10, 2007, 9:20 pm
Every now and then i run into a system with two oil burners conected to
under ground tank with two lines coming in feed and return and when
they are both running one will go off on safety,they have been running
fine for fifteen years,they have filters on each and no check
valves,the only way i know how to solve this problem is to install a
TIGER LOOP for each burner,can you tell me what the problem is and how
to solve,both also have new one stage pumps,thanks,oilman


Posted by on January 10, 2007, 9:36 pm
On 10 Jan 2007 18:20:29 -0800, oilman4627@comcast.net wrote:

>Every now and then i run into a system with two oil burners conected to
>under ground tank with two lines coming in feed and return and when
>they are both running one will go off on safety,they have been running
>fine for fifteen years,they have filters on each and no check
>valves,the only way i know how to solve this problem is to install a
>TIGER LOOP for each burner,can you tell me what the problem is and how
>to solve,both also have new one stage pumps,thanks,oilman

        Is the vent big enough ? Are the dip tubes ( all 4 )
positioned to avoid conflict with each other ? You could probably
alleviate the symptom by going to 1 pipe systems, but I don't
recommend that, IMO 2 pipe is much better.


--
Click here every day to feed an animal that needs you today !!!
http://www.theanimalrescuesite.com/

Paul ( pjm @ pobox . com ) - remove spaces to email me
'Some days, it's just not worth chewing through the restraints.'
'With sufficient thrust, pigs fly just fine.'
HVAC/R program for Palm PDA's
Free demo now available online http://pmilligan.net/palm/

Similar ThreadsPosted
Re: Carlin Oil burner problem August 23, 2007, 7:11 am
Re: Carlin Oil burner problem August 24, 2007, 9:20 pm
Gas Burner / Hot water system problem November 20, 2006, 9:56 am
Potential piping problems July 11, 2007, 8:31 am
oil burner smell November 3, 2009, 5:55 am
Beckett or Reillo Burner December 3, 2006, 12:18 pm
An oil burner control question January 17, 2007, 9:33 am
New Oil Burner? Is it Worth It? Please Advice March 13, 2007, 5:12 pm
Furnace burner comes on but blower does not November 24, 2007, 7:34 pm
Re: Burner Shutting Off Need Advice April 12, 2006, 7:28 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap