"water test" for residential heat exchangers - thoughts?

HVAC Discussions - Heating, ventilation and air conditioning. 

Page 1 of 3       1 2 3 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
"water test" for residential heat exchangers - thoughts? Todd H. 09-14-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Todd H. on September 14, 2006, 12:53 am

I'm curious on opinions from pro's of the water test for residential
heat exchangers advocated by Ellis Prach of
http://www.heatexchangerexperts.com/ In this test, the tech pulls the
blower, douses the exchanger with a water solution from a large
sprayer, and then looks inside the combustion area for water
penetration. If there's water getting in, they reason, you have a
breached heat exchanger that they recommend replacing it.

I'm suspicious of this Prach guy though... a self-proclaimed heat
exchanger expert, and evidently pontificates--in his seminars he holds
all over the country training HVAC techs--that he can even find leaks
in a heat exchanger that's 3 years old. His seminars are apparently
quite hands-on and he travels with several actual heat exchangers and
demonstrates trouble spots on each. I've talked to two attendees and
they concur on these points.

So, do y'all think this is a worthwhile diagnostic test that
correlates with real safety issues, or just a great way to sell new
furnaces and make this Prach guy rich giving seminars from companies
so willing to have him teach techs to find leaks in 3 year old heat
exchangers?

The whole thing seems to hinge on the assumption that if the heat
exchanger isn't water tight, then it isn't air tight, and the further
assumption that pressures inside the furnace are such that combusion
byproducts might actually make it into the airflow of such leakage
areas.

My own situation that motivates the question: a tech (from a
significant, well-respected company in Chicagoland that I've used for
years because they invest in training their techs rather well) had
attended a seminar by this man recently, and had come to give my 15
year old Carrier furnace the annual cleaning and once over. Perhaps
it was the age of the furnace, or the rust on it from the prior owner
not occupying hte house for the prior two years, but soething
compelled him to drop the blower and perform this new test he'd
learned recently. Now, this is a furnace that had a visual inspection
and tested CO free on all chambers last November for whatever that's
worth. I understand that for CO to form and get into ducts you need a
lot more than an HX breach.

Personally, I may go ahead and replace the furnace based on age and
the suspicion alone, and enjoy the comfort and efficiency afforded by
a newer 2-stage and/or variable speed furnace since my time horizons
in this home are long enough to get the payback.

But I remain curious what folks think about this test all the same,
and the likelihood that my current furnace _really_ has a safety
concern.

Thanks in advance for any constructive thoughts or discussion.

Best Regards,
--
Todd H.
http://www.toddh.net/

Posted by Bubba on September 14, 2006, 7:34 am
On 13 Sep 2006 23:53:38 -0500, t@toddh.net (Todd H.) wrote:

>I'm curious on opinions from pro's of the water test for residential
>heat exchangers advocated by Ellis Prach of
>http://www.heatexchangerexperts.com/ In this test, the tech pulls the
>blower, douses the exchanger with a water solution from a large
>sprayer, and then looks inside the combustion area for water
>penetration. If there's water getting in, they reason, you have a
>breached heat exchanger that they recommend replacing it.
>I'm suspicious of this Prach guy though... a self-proclaimed heat
>exchanger expert, and evidently pontificates--in his seminars he holds
>all over the country training HVAC techs--that he can even find leaks
>in a heat exchanger that's 3 years old. His seminars are apparently
>quite hands-on and he travels with several actual heat exchangers and
>demonstrates trouble spots on each. I've talked to two attendees and
>they concur on these points.
>So, do y'all think this is a worthwhile diagnostic test that
>correlates with real safety issues, or just a great way to sell new
>furnaces and make this Prach guy rich giving seminars from companies
>so willing to have him teach techs to find leaks in 3 year old heat
>exchangers?
>The whole thing seems to hinge on the assumption that if the heat
>exchanger isn't water tight, then it isn't air tight, and the further
>assumption that pressures inside the furnace are such that combusion
>byproducts might actually make it into the airflow of such leakage
>areas.
>My own situation that motivates the question: a tech (from a
>significant, well-respected company in Chicagoland that I've used for
>years because they invest in training their techs rather well) had
>attended a seminar by this man recently, and had come to give my 15
>year old Carrier furnace the annual cleaning and once over. Perhaps
>it was the age of the furnace, or the rust on it from the prior owner
>not occupying hte house for the prior two years, but soething
>compelled him to drop the blower and perform this new test he'd
>learned recently. Now, this is a furnace that had a visual inspection
>and tested CO free on all chambers last November for whatever that's
>worth. I understand that for CO to form and get into ducts you need a
>lot more than an HX breach.
>Personally, I may go ahead and replace the furnace based on age and
>the suspicion alone, and enjoy the comfort and efficiency afforded by
>a newer 2-stage and/or variable speed furnace since my time horizons
>in this home are long enough to get the payback.
>But I remain curious what folks think about this test all the same,
>and the likelihood that my current furnace _really_ has a safety
>concern.
>Thanks in advance for any constructive thoughts or discussion.
>Best Regards,

Seems you've already made up your mind but I'll give you my .03
worth. I previously worked for a national hvac company that adopted
this practice like it came from the bible. This company was also into
high pressure sales practices and tactics. One little twist they added
to the test was to make sure the heat exchanger was nice and hot right
before they started spraying water on the heat exchanger. Common sense
tells you that hot thin metal and cold water are not a good
combination for a homeowners heat exchanger. CO tests, detectors and
visual inspections and cameras are a more advanced way of checking
heat exchangers.
Bubba

Posted by Todd H. on September 14, 2006, 12:20 pm
> Seems you've already made up your mind but I'll give you my .03
> worth. I previously worked for a national hvac company that adopted
> this practice like it came from the bible. This company was also into
> high pressure sales practices and tactics. One little twist they added
> to the test was to make sure the heat exchanger was nice and hot right
> before they started spraying water on the heat exchanger. Common sense
> tells you that hot thin metal and cold water are not a good
> combination for a homeowners heat exchanger. CO tests, detectors and
> visual inspections and cameras are a more advanced way of checking
> heat exchangers.
> Bubba

Thankfully this company didn't do that! Since it's still a bit
A/C season, he didn't want to run the furnace to put the HX through
that thermal stress, but he did clean the burners and everything and
then was curious enough to do the inspection. It was done with a
room temp HX. He did a visual with mirror but I don't think I saw a
camera involved.

Tis interesting though how many different ways there seem to be to
check HX's.

--
Todd H.
http://www.toddh.net/

Posted by Stormin Mormon on September 14, 2006, 8:05 am
1) I thought combustion chambers were supposed to run dry. Isn't
adding a bunch of water a rust hazzard?
2) if you're getting zero monoxide, why are you continuing to test?
Trying to find a reason to think there is a leak?
3) The quote on the manual page that "most of the furnaces had a
crack" only means to me that he's found an indicator that shows
positive on everyone's furnace
4) solution, eh? Some kind of detergent stuff that really soaks
through? Doesn't mean that flue gasses go the other way.

I'm not going to waste a lot of time on this "new" technique.

--

Christopher A. Young
You can't shout down a troll.
You have to starve them.
.


I'm curious on opinions from pro's of the water test for residential
heat exchangers advocated by Ellis Prach of
http://www.heatexchangerexperts.com/ In this test, the tech pulls the
blower, douses the exchanger with a water solution from a large
sprayer, and then looks inside the combustion area for water
penetration. If there's water getting in, they reason, you have a
breached heat exchanger that they recommend replacing it.

I'm suspicious of this Prach guy though... a self-proclaimed heat
exchanger expert, and evidently pontificates--in his seminars he holds
all over the country training HVAC techs--that he can even find leaks
in a heat exchanger that's 3 years old. His seminars are apparently
quite hands-on and he travels with several actual heat exchangers and
demonstrates trouble spots on each. I've talked to two attendees and
they concur on these points.

So, do y'all think this is a worthwhile diagnostic test that
correlates with real safety issues, or just a great way to sell new
furnaces and make this Prach guy rich giving seminars from companies
so willing to have him teach techs to find leaks in 3 year old heat
exchangers?

The whole thing seems to hinge on the assumption that if the heat
exchanger isn't water tight, then it isn't air tight, and the further
assumption that pressures inside the furnace are such that combusion
byproducts might actually make it into the airflow of such leakage
areas.

My own situation that motivates the question: a tech (from a
significant, well-respected company in Chicagoland that I've used for
years because they invest in training their techs rather well) had
attended a seminar by this man recently, and had come to give my 15
year old Carrier furnace the annual cleaning and once over. Perhaps
it was the age of the furnace, or the rust on it from the prior owner
not occupying hte house for the prior two years, but soething
compelled him to drop the blower and perform this new test he'd
learned recently. Now, this is a furnace that had a visual inspection
and tested CO free on all chambers last November for whatever that's
worth. I understand that for CO to form and get into ducts you need a
lot more than an HX breach.

Personally, I may go ahead and replace the furnace based on age and
the suspicion alone, and enjoy the comfort and efficiency afforded by
a newer 2-stage and/or variable speed furnace since my time horizons
in this home are long enough to get the payback.

But I remain curious what folks think about this test all the same,
and the likelihood that my current furnace _really_ has a safety
concern.

Thanks in advance for any constructive thoughts or discussion.

Best Regards,
--
Todd H.
http://www.toddh.net/



Posted by Al Moran on September 14, 2006, 9:00 am
On Thu, 14 Sep 2006 12:05:25 GMT, "Stormin Mormon"


>I'm not going to waste a lot of time on this "new" technique.


It's a valid technique you knob. Will you waste time fighting the
lawsuit that is sure to follow when your incompetent ass kills
someone? Your stupidity never ceases to amaze!

Page 1 of 3       1 2 3 > last >>
Similar ThreadsPosted
water line air test September 17, 2007, 8:19 pm
Chilled water for residential forced air AC systems? August 15, 2006, 6:05 pm
geothermal water-water heat exchanger February 25, 2007, 1:23 pm
geothermal water to water heat pump August 6, 2007, 10:20 am
Carrier Residential Heat Pump May 21, 2008, 2:13 pm
Breaking into Residential (possibly commercial) Oil Heat Servicing February 23, 2007, 4:35 am
air source heat pump, split system, supply water for slab heat/cool February 15, 2008, 8:27 pm
do high-end residential heat pumps with variable speed air handlers truly vary the speed to control humidity? May 9, 2007, 9:24 am
Re: Urine Test December 11, 2007, 8:42 pm
Re: Urine Test December 12, 2007, 3:34 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap