Home Page link

Any US Distributors For Schneider Electric Of Canada ?

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Any US Distributors For Schneider Electric Of Canada ? Robert11 08-07-2005
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Robert11 on August 7, 2005, 11:44 am


Hello:

Anyone happen to know if there are any U.S. distributors for Schneider
Electric of Canada ?

Apparently they manufacture brand new replacement Stab-Lok circuit breakers
for old FPE panels.

There seem to be several places in the U.S. offering re-manufactured, or
reconditioned breakers, but only Schneider seems to still make brand new
replacement ones.

Tried Google, but couldn't come up with any.

Thanks,
B.




PexSupply Save 10 468x60
Posted by Tony Hwang on August 7, 2005, 4:15 pm


Robert11 wrote:

> Hello:
>
> Anyone happen to know if there are any U.S. distributors for Schneider
> Electric of Canada ?
>
> Apparently they manufacture brand new replacement Stab-Lok circuit breakers
> for old FPE panels.
>
> There seem to be several places in the U.S. offering re-manufactured, or
> reconditioned breakers, but only Schneider seems to still make brand new
> replacement ones.
>
> Tried Google, but couldn't come up with any.
>
> Thanks,
> B.
>
>
Hi,
Ask the question at alt.home.repair.
Tony


Posted by Jake on August 7, 2005, 5:21 pm


Robert11 wrote:
> Hello:
>
> Anyone happen to know if there are any U.S. distributors for Schneider
> Electric of Canada ?
>
> Apparently they manufacture brand new replacement Stab-Lok circuit breakers
> for old FPE panels.
>
> There seem to be several places in the U.S. offering re-manufactured, or
> reconditioned breakers, but only Schneider seems to still make brand new
> replacement ones.
>
> Tried Google, but couldn't come up with any.
>
> Thanks,
> B.
>
>

Robert,

FPE panels became known fire hazards (still being debated in some
environs) because of their tendency for failure to open after a few
trips. This was particularly true in double pole breakers.

Look at this site, which probably contains more information than you'd
ever want to know on the subject:

http://www.inspect-ny.com/fpe/fpepanel.htm

I *thought* Siemens now owned the Federal line, and had heard that new
parts were still available up to several years ago. Most people just
replace the aging and suspect panels with a more reliable design.

Schneider Electric is the parent company of Square D, so perhaps a
Square D distributor could help you further.

Jake



Posted by on August 8, 2005, 11:57 am


I think the answer is no. They are only sold in Canada. Sometimes you
can get them off eBay. I have one in my panel. I think they are
perfectly fine. I know someone always posts how they are supposedly a
fire hazard, but if you read the documents, it's only the double pole
breakers that don't trip properly. I have one of these panels, and
I've tested every breaker on it, and mine works fine.



Posted by Bud on August 9, 2005, 5:31 pm


scott21230@gmail.com wrote:
> I think the answer is no. They are only sold in Canada. Sometimes you
> can get them off eBay. I have one in my panel. I think they are
> perfectly fine. I know someone always posts how they are supposedly a
> fire hazard, but if you read the documents, it's only the double pole
> breakers that don't trip properly.

If you read the "documents" the single pole breakers tend not to trip at
135% of load, the bus connections can fail, the breakers may not be
retained by the bus (may come loose), and other problems. FPE
fraudulently supplied information to UL and UL wound up delisting most
of the FPE line. Reliance Electric bought FPE and discovered the
problems; they sued the seller of FPE and setteled for about 43 million
dollars to cover liability. I believe there is currently a class action
law suit in New Jersey.

See the site in another post
http://www.inspect-ny.com/fpe/fpepanel.htm - this site links to a
lot of information

Some sites linked to by the site above that are of particular interest:

http://www.inspect-ny.com/fpe/fpestlouis.htm - the report of tests done
on breakers and reported to an association of home inspectors - also
includes information on bus failures

http://www.codecheck.com/pdf/electrical/240overcurrent/FPE%20Article%20f
rom%20DH%20-%20Nov2003.pdf - a lot of info

http://www.inspect-ny.com/fpe/fpe.html - the long version of the first
site without the links.

I have one of these panels, and
> I've tested every breaker on it, and mine works fine.
>
How do you test them? Apply an over current and test for appropriate
trip time? Look at the bus connections to see if any are failing? I
doubt a homeowner has the equipment ot test the breakers or knowledge to
inspect.

Bud--



Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
stellenangebot industrie Schneider Schneiderin stellenangebot elektro jobangebote hannover June 25, 2008, 5:31 am
Toronto,Canada - anyone verify this? September 23, 2005, 11:59 pm
Is Canada 120V or 220v? November 8, 2005, 3:06 pm
IPEX Supplier Canada? March 21, 2006, 5:38 pm
Venting - HTH/Arch in Canada April 26, 2007, 2:53 pm
Re: Rewiring house in Ontario, Canada June 17, 2005, 11:45 am
Re: Rewiring house in Ontario, Canada June 19, 2005, 2:25 am
Electrical Code Question (Canada) January 28, 2006, 4:49 pm
Electrical Upgarde questions - Ottawa Canada January 22, 2006, 2:10 pm
Left handed drill bits in Calgary... or at least Canada??? June 18, 2006, 5:49 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap