Posted by Mike Dobony on July 15, 2006, 11:13 pm
"MDT at Paragon Home Inspections, LLC"
> > The one I saw had no sensors.
>
> FWIW, off-hand I'm not sure that's a good idea. It seems to me such a
> "flow detector" would have to trip at pretty low flow rates to be
> effective - even a "small" leak from a water heater, dishwahser, or
> laundry can cause a lot of damage if undetected - and if it can detect
> those, it would see to me it would be nuisance-tripped by (for example)
> a refrigerator ice maker.
>
That would be my thoughts also. Just wondering if I rememberd correctly and
intrigued by the idea.
|

| |
Posted by Dave on July 15, 2006, 11:11 pm
Mike Dobony wrote:
> Seems to me I saw an ad once for an atuomatic water shutoff valve which
> activates if a pipe bursts or water heater tank breaks open. Seems to me it
> was activated by a sudden large drop in water pressure. Anybody familiar
> with anything like this?
Unless you have pipes that have been frozen I don't see why you would
expect them to burst. The washing machine and water heater probably
ought to be near floor drains.
|
|
Posted by MDT at Paragon Home Inspection on July 16, 2006, 8:21 am
In my experience, the big five are:
- Water heaters: basement floor drains may be clogged, floor coverings
can wick water long distances, water wicked to walls can wick up. And,
people store a lot of valuable stiff and/or absorbant materials on
basement floors.
- Washers, with and w/o functioning drain pans. No functioning pan: see
above. Pan: hose leaks at connection to plumbing, water sprays beyond
pan, see above. Special case, washers in hall closets above first
floor, and condos. If the latter, and a unit above: pan or no pan, the
first place to look is UP.
- Kitchens: dishwashers and refrigerator ice-makers. Ever see a drain
pan under one of those?
In my rental units, I use these:
http://www.plumbingworld.com/automaticwatershutoff.html
- AC condensate drains, especially air handlers in attics: Almost never
inspected by homeowners. Primary drain clogs, secondary is not
installed and no cut-off switch or switch, or switch not properly
installed or connected, or secondary drains out of plain view, or
people don't pay attention when it starts running. Condensate is now
running down on or into walls.
- Condensate pump at furnace w/o functioning cut-off switch for
furnace / AC. Pump fails: condensate now draining on or into
structure..
Then, when things get wet, people go crazy over mold: "I saw this house
on Sixty Minutes...."
IMO in most cases this isn't the homeowners fault - the problem rather
is that there is little incentive for the manufacturers or installers
of such systems to think through the longer-term implication of
failures, so the level of protection provided is unusually the minimum
specified by building codes, if that.
So, stuff "floods".
As a home inspector I can (and should) note if a structure is a
vacation home, and ask if someone's job is likely to mean the house
will be unoccupied for substantial periods, and if so point out that
if so there is an increased risk of water damage. And I can verbally
note the lack of pan on a washer, or even the lack of an auto-shutoff
on a dishwasher during an inspection, and/or include it as an item in
the "suggestions an comments" section of my report.
But as a comment in a three hour inspection, or a 30-40 page report,
the reality is that only a minority of buyers will absorb this advice.
And of those, on a tiny minority of cash-strapped home buyers would
make avoiding what they perceive as relatively low-probability event a
priority - I'm pleased if they seem to taking my comments about the
much larger risk of a 20 year old water heater located nowhere near a
drain seriously - maybe they WON'T be stacking boxes with last years
financial returns or irreplaceable family letter and photos on the
floor next to it, after all...
Michael Thomas
Paragon Home Inspection, LLC
Chicago, IL
mdtATparagoninspectsDOTcom
eight47-475-5668
|
Page 2 of 2 << first < 1 2
| Similar Threads | Posted | | Automatic Emergency Water Shutoff Device? | October 30, 2006, 12:40 am |
| How do I shutoff or block sewer line while replacing the shutoff valve? | November 22, 2007, 4:25 pm |
| The nut for Main Water shutoff (Ball valve) got wet when turning | March 30, 2007, 10:04 pm |
| Does an automatic shutoff energy saver light switch exist? | January 21, 2007, 6:05 pm |
| New shutoff valve - how to sweat in? | May 15, 2006, 2:13 pm |
| Automatic sprinkler valve leaking | July 23, 2006, 4:14 pm |
| pool shutoff valve replacement | June 22, 2005, 2:28 pm |
| Gas Shutoff Valve Location - In Wall Cavity? | October 17, 2005, 9:20 am |
| Old Gas Lamp, Saddle Valve Connection and No Shutoff for Line | July 10, 2007, 1:31 pm |
| What to do with water shutoff valves and water heater when on vacation? | November 19, 2006, 6:38 pm |
|
|