Posted by on July 30, 2006, 9:19 am
I have tried every GFI swith that is on outlets in the house. Then, I
look in the breaker box and the breaker for the spa tub has it labeled
as a "GFI". Is THAT the required GFI switch for the tub or does there
necessarily have to be one in the house somewhere.
It showed up on an inspection report that he could not locate the GFI
for the tub - so now I am looking for it.
Thanks.
|

| |
Posted by Amy L on July 30, 2006, 9:22 am
Is the breaker of GFI breaker?
Amy
>I have tried every GFI swith that is on outlets in the house. Then, I
> look in the breaker box and the breaker for the spa tub has it labeled
> as a "GFI". Is THAT the required GFI switch for the tub or does there
> necessarily have to be one in the house somewhere.
>
> It showed up on an inspection report that he could not locate the GFI
> for the tub - so now I am looking for it.
> Thanks.
>
|
|
Posted by on July 30, 2006, 9:27 am
If the breaker in the box for the spa is a GFCI breaker, then that is
all that is required for GFCI protection of the spa. However, be sure
that the breaker is in fact a GFCI type. Sometimes a label could be
applied next to a regular breaker, indicating that a GFCI is somewhere
on that circuit. If it's a true GFCI breaker, it will have the usual
test button. If there is a GFCI in the panel for the spa, the home
inspector would have to be incompetent to not be able to find and
correctly identify it.
|
|
Posted by RBM on July 30, 2006, 9:27 am
If the circuit breaker in the panel, labeled for the tub is a GFCI and
actually feeds the tub, that is sufficient. If there is only a standard
circuit breaker in the panel feeding the tub, there must be a GFCI device
between it and the tub. Often it is a GFCI outlet under the tub, with the
tub equipment plugged into it.
>I have tried every GFI swith that is on outlets in the house. Then, I
> look in the breaker box and the breaker for the spa tub has it labeled
> as a "GFI". Is THAT the required GFI switch for the tub or does there
> necessarily have to be one in the house somewhere.
>
> It showed up on an inspection report that he could not locate the GFI
> for the tub - so now I am looking for it.
> Thanks.
>
|
|
Posted by Tom The Great on July 30, 2006, 11:17 am
On 30 Jul 2006 06:19:30 -0700, tommyclark46@yahoo.com wrote:
>I have tried every GFI swith that is on outlets in the house. Then, I
>look in the breaker box and the breaker for the spa tub has it labeled
>as a "GFI". Is THAT the required GFI switch for the tub or does there
>necessarily have to be one in the house somewhere.
>
>It showed up on an inspection report that he could not locate the GFI
>for the tub - so now I am looking for it.
>Thanks.
GFCI doesn't mean the actual item or device, but the protection the
device offers. So when something needs to be GFCI protected, this can
be accomplished with the two most common devices, a GFCI
receptacle(normal and faceless) and a GFCI breaker.
So if you have a GFCI breaker, and labeled for the tub, I would test
it. Press the test button to verifiy it is safely operating, and see
if the tub losses power.
Little inside secret, Home Inspectors don't have to experts about all
systems in a house. I've heard of older homes getting written up for
NO GFCI protection in the kitchen, becaue there was no ground. The
GFCI's present worked, and tested sat, but there was NO ground. The
inspector said there HAD to be a ground. The NEC tells you to use
GFCI receptals on ungrounded circuits, to provide ground protection.
Now remember, I'm not there, so only guessing. Only a qualified
electrician should work on your equipment, per the NEC.
good luck, imho,
tom @ www.IRantAndRave.com
|
Page 1 of 2 1 2 > last >>
| Similar Threads | Posted | | GFCI outlets required with a GFCI Breaker? | July 15, 2008, 3:10 pm |
| where find? | July 14, 2006, 3:00 pm |
| How do I find it? | January 24, 2007, 6:27 pm |
| Help me find this please... | April 20, 2007, 11:42 am |
| Where can I find this | May 1, 2007, 8:55 am |
| where to find............................... | December 13, 2007, 11:40 am |
| New house - how to find your well? | October 19, 2005, 12:20 pm |
| How to find the best service? | May 15, 2006, 9:11 am |
| where find online CAD? | July 9, 2006, 2:21 pm |
| Cant find Ice Cubes to fit | October 20, 2006, 8:22 pm |
|
|