Posted by kool on May 16, 2007, 4:42 pm

>>
>>
>> > Living in Quebec which supposedly has the cheapest hydro rates in
>> > North America I'm considering changing from an old oil fired boiler to
>> > an electric boiler.
>> > I have a relatively small house and the much smaller boiler unit, no
>> > more oil tank, cleanliness and apparently faster heating time really
>> > appeals me.
>> > Anyone have thoughts on this?
>> > Thanks in advance
>>
>> Unless you have a big enough hydro service now, don't forget to include
>> an
>> upgrade to probably a 200 amp. supply in your cost calculations. An
>> indoor/outdoor reset controller would also save on operating costs.
>
> What's an indoor/outdoor reset controller?? I know there's an
> optional outdoor sensor on some models that heats the water
> temperature relative to the outside temperature -dunno if that's what
> you're referring to.
> Yes have the entrance upgrade factored in. (about $1400 Cdn)

"In hydronic heating systems -- also known as hot-water systems -- a
single-stage reset control device can sense changes in outdoor temperature
and adjust the temperature of the hot water that circulates through the
system. The result increases the efficiency of the boiler without
sacrificing comfort.

These control devices, also called indoor-outdoor reset controls, cost from
about $500 installed, and studies show that they can reduce annual fuel
costs anywhere from 5 to about 25 percent. The most common range of savings,
however, is in the 12 to 15 percent range."

Reset controls have been popular in Europe, which has experienced high fuel
costs for more than 30 years. The technology has been common in commercial
heating in the United States for nearly as long. With the cost of home
heating fuel skyrocketing, these controls are becoming more popular in
residential applications.

"They're excellent," says Ed Schoen of Prestige Heating Service Inc. in
Massapequa. "Most of the time, I find people are buying them with the
installation of a new boiler. ...Really, the control is part of an
energy-efficient package, which includes everything from a high-efficiency
boiler and a digital, programmable thermostat to a well-insulated home."

Richard Levi, part owner of Comfort Specialists in Oceanside, also is a fan
of the indoor-outdoor reset controls. "In a new boiler installation, it's a
no- brainer," Levi says. "Oil and gas, the prices are not going down, and
over the long haul this saves on fuel."

Levi, however, says recent technology is the reason the controls are
beginning to make a dent in the residential market. "Years ago, these
controls were not very reliable because they were made of big boxes with
mechanical relays that broke down frequently," he says. For the past 10
years, Comfort Specialists has been installing reset controls for commercial
heating systems. "I've never had one go bad on me yet," Levi says.

The reset control devices are manufactured by companies such as Tekmar
Controls, Honeywell and Johnson Controls. Here's how they work:

The size of a heating system is calculated, in part, based on the coldest
day of the year in a given climate. "Since every day is not the coldest day
of the year, a heating system often is running 'oversized' and
inefficiently," says Don Rathe, owner of Rathe Associates Inc., a Syosset
company that distributes heating and cooling components, including reset
controls by Tekmar.

So whether the thermostat is set at 68 degrees or 78 degrees, a hydronic
heating system circulates water at a maximum temperature of between 180
degrees and 190 degrees. In mild or moderate temperatures, this output is
excessive. The boiler heats and circulates water to the hottest temperature,
even though there isn't a maximum demand for heat.

With a reset device installed, an air sensor mounted on the exterior of the
north side of the building (commonly the coldest part of the exterior)
senses any change in outside air temperature. The air sensor communicates
this outside temperature change to a control box mounted on the boiler.
Another sensor is installed on the pipe that supplies water to the boiler.
The control box is programmed to heat the water that circulates through the
boiler based on the outside temperature. So on a 40-degree day, water might
be circulated at 150 degrees instead of 180 degrees or 190 degrees.

"The boiler doesn't have to work as hard to heat the water, so there's a
savings in fuel," Rathe says. "The thermostat remains the brains of the
heating system, but the reset control provides more support-that's the
perfect word - for the thermostat and the system to work more efficiently."

Although the control box is factory programmed, it also can be re-programmed
to a homeowner's comfort and demands, Rathe says.

Levi says the bigger the heating system, the better the savings. "Systems
with large quantities of water, bigger homes, offices and apartment
complexes, this is where you see the most benefit," Levi says. "On a smaller
system, you get savings, but I think you also get a lot more comfort. You
don't have these bursts of heat coming at you and then have the system
shutting down.

"There's a more consistent output of heat."




Posted by hallerb@aol.com on May 16, 2007, 10:41 pm

> Yes have the entrance upgrade factored in. (about $1400 Cdn)- Hide quoted text
-
>
> - Show quoted text -

you will likely need 400 amps for whhole use heating, price sounds low



Posted by Ladykins on March 28, 2008, 6:44 am
Ladykins had written this in response to
http://www.www.thestuccocompany.com/maintenance/Conversion-Oil-fired-boiler-to-Electric-boiler-217798-.htm
:
Hi can anybody help me? I have lived at my house for 3 years and have a
behind the wall old fashioned boiler in the dining room, like a lot of
terraced houses! - it is a LANDIS & GYR controlled timer system. It has
always worked fine but today I switched the heating on (constant) and
behind the wall seemed to be making a loud noise and the flames were
visible and burning quite ferociously

If anyone knows what this problem is or might be, please contact me . I
have turned my heating for the radiators and water off

Thanks

-------------------------------------
bripen@sympatico.ca wrote:


> Living in Quebec which supposedly has the cheapest hydro rates in
> North America I'm considering changing from an old oil fired boiler to
> an electric boiler.
> I have a relatively small house and the much smaller boiler unit, no
> more oil tank, cleanliness and apparently faster heating time really
> appeals me.
> Anyone have thoughts on this?
> Thanks in advance






##-----------------------------------------------##
Delivered via http://www.www.thestuccocompany.com/
Building Construction and Maintenance Forum
Web and RSS access to your favorite newsgroup -
alt.home.repair - 280930 messages and counting!
##-----------------------------------------------##

Page 3 of 3       << first < 1 2 3
Similar ThreadsPosted
Oil-Fired Water Boiler Decision May 15, 2006, 1:38 pm
Chimney liner for oil fired boiler November 6, 2007, 12:03 am
Oil-fired boiler, huge amounts of soot February 11, 2006, 9:35 pm
Slant Fin Oil Fired Boiler - Repair or replace? March 17, 2006, 2:46 am
Oil fired Boiler Loud Bang on Start Up. December 27, 2007, 10:35 pm
Oil-fired boiler, power-vent, outside combustion setup December 21, 2005, 9:59 am
Adding a water heater and not replacing the oil fired boiler February 9, 2006, 10:38 pm
Weil McLain WTGO Oil Fired Boiler Qestion October 16, 2006, 11:15 pm
Steam Boiler conversion November 6, 2005, 7:28 pm
Help - I have a back boiler and want a combi boiler fitted but have plastic pipes! November 22, 2005, 2:26 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap