Posted by on June 1, 2007, 2:56 pm
On Fri, 01 Jun 2007 13:16:54 -0400, gfretwell@aol.com wrote:
>
>>I only like to have my well pump on at my cottage when I am there, but the
>>switch is in a really inconvenient place. I would like to put a relay on
>>it, so I can put the switch in a better place.
>>
>>1) Can you suggest an online supplier of reasonably priced relays? I bought
>>one for my table saw a few years back, but can't remember where.
>>2) What is the requirement for wire size? They only use 30ma or something
>>like that; do they require wiring matched to the the breaker anyhow?
>>
>>Thanks
>>
>
>
>Try this
>http://dale-electric.com/search.php?itemnumber=&manufacturer=&keywords=rr7&category=&resultsPerPage=25
This is a latching relay that you control with 24vac. Hit one wire it
is on, hit the other it is off. 3 wire low voltage cable can connect
an unlimited number of switches foir each relay. The relay fits in a
regular 1/2" box knockout replacing the switch. The coil and low
voltage stays outside the box so it is isolated.
|