Posted by JoeSpareBedroom on September 20, 2007, 3:03 pm
> On Sep 20, 2:44 pm, alvinamo...@notmail.com wrote:
>> wrote:
>>
>>
>>
>>
>>
>> >On Thu, 20 Sep 2007 08:34:26 -0700, Mikepier wrote:
>>
>> >> I have to cut off a section of cast iron waste pipe in my attic to tie
>> >> in a vent .My concern is when I cut off the section of pipe, the
>> >> weight of the upper part of pipe would cause it to possible come
>> >> loose from the roof flashing and sink, thus causing a roof leak. The
>> >> last thing I want to do is open up a can of worms by doing this job. I
>> >> was wondering if I should be concerned or if anyone else has done a
>> >> job like this, what advice to offer. Thanks
>>
>> >You didn't state exactly where you are working on the vent pipe.
>> >Chances
>> >are you will see very little, if any, movement if you work below
>> >existing
>> >vents tied into the main pipe. It would still be a wise choice to
>> >secure
>> >the uppermost part of the pipe with strap supports designed to hold
>> >pipes
>> >securely.
>>
>> >A reciprocating saw would seem to move the pipe less than doing so with
>> >a
>> >handsaw.
>>
>> >I did exactly what you are doing several years back. That vent was cast
>> >iron. I had to cut the pipe in the basement to reroute tub and stool.
>> >There were enough pipes above me to support the vent without moving.
>>
>> >Reflashing or caulking the existing flash when done makes sense.
>>
>> If all you are doing is adding a vent, you can buy strap around
>> devices. Then cut a square hole in the cast pipe with an angle
>> grinder and attach the "strap on". You dont need to cut the whole
>> pipe. After all, it's only a vent.- Hide quoted text -
>>
>> - Show quoted text -
>
> Is there a place online I can find out more about this?
>
Open your yellow pages phone book and find a plumbing supply store. Go there
and ask.
|