I saw a "weird to me" circuit and would like to learn what it is.
Inside the junction box there was one hot wire running through it and
passing out of it through the other end down the conduit. Then inside
the 2 neutrals and 2 grounds was wire nutted togther with a outlet that
is underneath the junction box. So why is the other hot running
through but the 2 neutral were wire nutted with the outlet below?


Posted by RBM on January 4, 2007, 9:31 pm


It sounds like you may be describing an Edison circuit, which is two hot
legs,(of different potential) sharing a neutral. One hot leg is feeding the
outlet,the second hot leg is going down the conduit to something else, and
the neutral is pigtailed to the outlet and continuing to the second circuit.
Neutrals of this type of circuit can't be dependent on devices like outlets,
so they're typically pigtailed



> I saw a "weird to me" circuit and would like to learn what it is.
> Inside the junction box there was one hot wire running through it and
> passing out of it through the other end down the conduit. Then inside
> the 2 neutrals and 2 grounds was wire nutted togther with a outlet that
> is underneath the junction box. So why is the other hot running
> through but the 2 neutral were wire nutted with the outlet below?
>



Posted by HeyBub on January 4, 2007, 10:17 pm


super2324us@yahoo.com wrote:
> I saw a "weird to me" circuit and would like to learn what it is.
> Inside the junction box there was one hot wire running through it and
> passing out of it through the other end down the conduit. Then inside
> the 2 neutrals and 2 grounds was wire nutted togther with a outlet
> that is underneath the junction box. So why is the other hot running
> through but the 2 neutral were wire nutted with the outlet below?

If good-is-good, better-is-better?



Similar ThreadsPosted
branch electric box question August 21, 2005, 6:30 pm
Question? Apollo, Gas or Electric, etc. November 15, 2006, 11:10 am
Question? Apollo, Gas or Electric, etc. November 15, 2006, 11:11 am
Electric drill question February 19, 2007, 4:23 pm
electric dryer question September 15, 2007, 11:48 pm
Electric Stove question. September 27, 2007, 12:40 pm
electric inspection question January 1, 2008, 6:13 pm
electric code question March 15, 2008, 4:39 pm
electric metering question September 23, 2008, 8:29 pm
Electric concrete mixer question November 7, 2005, 5:16 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap