>it's easy to say "take control of your own life" but when a building
>inspector is standing there telling you you must have vent space period,
>what are you going to do?
Get an architect or PE to sign an "unvented" drawing?
>... if i was building my own house and i didn't have to deal with
>inspectors, i wouldn't vent the roof either...but i would also be very anal
>retentive about my vapor barrier.
Sure. And there are degrees of venting. With near-perfect vapor barriers on
both sides, a small vapor barrier or roof leak could make a lake. Perhaps
the roof should be slightly less airtight than the ceiling, with a ridge
vent but no wind-whistling chutes.
If I were building a new house, I might put insulation in the attic floor
and make the steep south roof clear Dynaglas polycarbonate plastic and make
the underside of the north roof white and collect warm air and light in
the attic in wintertime, with a few simple skylights in the attic floor,
with no venting in wintertime.
Nick
|
|
Posted by on December 11, 2006, 6:05 pm
nicksanspam@ece.villanova.edu wrote:
>
> >> >Here in the southern US, not leaving a place for ventilation will cost
> >> >you a roof job about 10 years before it should.
> >>
> >> Why would you say that? Seems unlikely to me, if there's no chance of
> >> condensation from moist house air leaking up under the roof.
>
> >Because that's how cathedral ceilings are built base on years of
> >construction experience...
>
> You might say the same about shark repellent in Kansas :-)
>
> Nick
And you might say that you're an idiot, giving out advice based on
equations, without knowing anything about the real world, construction,
or how roofs are properly ventilated.
|
|
Posted by m Ransley on December 12, 2006, 7:56 am
Research your code and recommended energy code and guidlines. R 20-R28
are substandard and inneficient. Your ceiling is where most your heat
loss is. R 35 in Zone 5 is considered not optimal, R 60 is. I dont know
your Zone but going to R 100 is getting more common in cold areas. You
need an airspace but I dought you need 2", 1" should do, Foam chutes are
cheap and easy to install. Furring out 2" is a good idea. For the best
performance spray on foam, there are types with R7 per " , twice that of
fiberglass. Also Fiberglass looses efectivness at extreme cold, maybe
near 50-60% at below zero temps. A vapor barrier is needed on
fiberglass, not foam, and inside next to the sheeting. 6.5" of closed
cell blown in foam is R 45, it may impress you but its still not an
optimal R value. Research, www.Energystar.com will help. Insulation
manufacturers Dow, Owens Corning etc will recommend maybe R60. I will
bet your Govs green sites might be even higher, R 70++, I dought your
code is under R35 unless you are on a coast with completly moderate
temps, but in canada? What you do now will be it, so if you can do it
go for the maximun as it will have a big payback and increase your
houses value.
|
|
Posted by Paul M. Eldridge on December 11, 2006, 7:57 pm
I don't wish to take sides in this argument and I certainly have no
practical expertise in this area, but the following article discusses
both "cold" and "hot" (i.e., vented and unvented) roof design in
colder climates; more specifically, Alaska.
See
http://www.north-rthn.org/french/f-factsheets/Attics-roofs-french.html
As to whether or not one should follow code, that's a personal call
but it would seem somewhat foolhardy to do otherwise. If this should
become an issue with the inspector, who do you think will have the
final say?
Cheers,
Paul
On 11 Dec 2006 14:20:34 -0800, trader4@optonline.net wrote:
>Because that's how cathedral ceilings are built base on years of
>construction experience. You provide a space between the insulation
>and the sheathing so that air can move from soffit to peak, where it
>exists via a ridge vent or other venting mechanism. I doubt you;d get
>a building inspector to pass off on an unventilated cathederal ceiling.
> Besides moisture, what do you think having no air flow under the
>sheathing is going to do to the life of the roof when it gets to 150 in
>the summer?
|
|
Posted by bowgus on December 11, 2006, 9:05 pm
Chris wrote:
> I have to add fiber glass insulation on my cathedral roof, for a small
> cottage 16' x 24', new construction, in Canada.
> The roof rafters are 2" x 8". For that size, I should use R20
> (6") in order to keep 2" for ventilation on the top of insulation.
> I though I could to be able to use add another 2" x 2" lumber in
> order to extend the rafters wide to 2 x 10 (instead of 2 x 8) and to
> use R28 (8") insulation instead of R20 (6"). Is that a big
> difference for R-value? The cottage is used to spend weekends and some
> vacation days and not (yet!) for permanent living.
> What would you recommend to me?
> And another question: In order to keep the 2" for ventilation I
> though to use raft-R-mate. Is it wrong to put this raft-R-mate the
> entire long of rafters or only at the beginning should be enough?
>
> Thank you,
> Chris
Fwiw ... R20 conductance is .050 ... 95% efficient, and R28 conductance
is .036 ... 96.4% efficient or not much of a difference. And you didn't
say but just in case, a ridge vent is the perfect partner for that
raft-R-mate (although I would think if the fiberglass is installed
carefully the raft-R-mate should not be required). And of course a
completely sealed vapor barrier.
|
Page 4 of 6 < 1 2 3 > last >>
| Similar Threads | Posted | | Mount new ceiling fan at peak of cathedral ceiling | May 17, 2008, 2:22 pm |
| Cathedral ceiling drywall sag? | December 25, 2006, 2:52 pm |
| Insulate Cathedral Ceiling | September 2, 2007, 12:33 am |
| Insulating cathedral ceiling | September 2, 2008, 4:27 pm |
| Flat ceiling to cathedral or open box? | July 11, 2005, 2:54 am |
| Flat ceiling to cathedral or open box? | July 8, 2005, 9:17 am |
| Re: Crown molding on a cathedral ceiling | July 5, 2006, 8:26 am |
| Cathedral ceiling or 2nd floor unused room | November 21, 2005, 4:03 pm |
| Best method to install beadboard on cathedral ceiling | December 29, 2005, 2:58 pm |
| I need some advice about retro-insulating a cathedral ceiling. | July 16, 2006, 3:31 pm |
|
|