Posted by M.Joshi on September 5, 2006, 10:22 am

Hello,

The water from our water tank in the loft keeps overflowing out of the
overflow pipe.

We recently replaced the ball valve and I checked the level at which it
shuts off the water however, the water has started to overflow again?




--
M.Joshi

AppliancePartsPros.com, Inc.
Posted by Speedy Jim on September 5, 2006, 1:02 pm
M.Joshi wrote:

> Hello,
>
> The water from our water tank in the loft keeps overflowing out of the
> overflow pipe.

Might also post to this group:

UK.D-I-Y


Posted by Noozer on September 5, 2006, 1:17 pm

>
> Hello,
>
> The water from our water tank in the loft keeps overflowing out of the
> overflow pipe.
>
> We recently replaced the ball valve and I checked the level at which it
> shuts off the water however, the water has started to overflow again?

Water pressure too high?



Posted by George E. Cawthon on September 5, 2006, 4:48 pm
M.Joshi wrote:
> Hello,
>
> The water from our water tank in the loft keeps overflowing out of the
> overflow pipe.
>
> We recently replaced the ball valve and I checked the level at which it
> shuts off the water however, the water has started to overflow again?
>
>
>
>
Must be British. The valve in a tank is not a
ball valve. Presume you mean that a ball shaped
float is hooked to the valve (probably by means of
a solid rod). For that type of system you simply
bend the rod between the valve and the float so
that the water level turns off about 1/8-1/4 inch
below the top of the overflow. You need to bend
the rod down so that the valve closes at a lower
water depth.

Posted by George E. Cawthon on September 5, 2006, 5:53 pm
George E. Cawthon wrote:
> M.Joshi wrote:
>> Hello,
>>
>> The water from our water tank in the loft keeps overflowing out of the
>> overflow pipe.
>>
>> We recently replaced the ball valve and I checked the level at which it
>> shuts off the water however, the water has started to overflow again?
>>
>>
>>
>>
> Must be British. The valve in a tank is not a ball valve. Presume you
> mean that a ball shaped float is hooked to the valve (probably by means
> of a solid rod). For that type of system you simply bend the rod between
> the valve and the float so that the water level turns off about 1/8-1/4
> inch below the top of the overflow. You need to bend the rod down so
> that the valve closes at a lower water depth.

Forgot to mention that you should check for free
movement of the ball float. Any interference and
you will be unable to get a consistent water level.

Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Brass Ball Valve,Gas Valve,Needle Valve,Angle Valve Sale on good price November 27, 2006, 12:48 pm
Valve,butterfly valve,ball valve,check valve,globe valve April 14, 2006, 4:23 am
Thermostatic Mixing Valve, or a coupla' check valves and a ball valve? December 28, 2005, 8:10 pm
Water Heater Install: Replace gate valve with ball valve March 27, 2007, 5:22 pm
Possibly faulty seal beneath the flush valve in a 1935 antique Toilet July 24, 2006, 5:56 pm
Gate Valve or Ball Valve September 8, 2005, 4:30 pm
Re: Stop valve or ball valve? May 25, 2008, 7:53 am
Re: Stop valve or ball valve? May 25, 2008, 8:43 am
Re: Stop valve or ball valve? May 25, 2008, 8:01 pm
Soldering Ball Valve April 9, 2006, 8:57 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap