Posted by TrailRunner on September 18, 2006, 4:29 pm
I have a Federal Pacific fuse panel. I don't have problems with the
panel. But, it is a split bus panel. Should the panel be replaced if
I am not having problems? It's a 200 amp panel.

Thanks,

Dan


Posted by RBM on September 18, 2006, 7:22 pm
If it's a fuse panel, you may want to upgrade to a circuit breaker panel
just for the convenience


>I have a Federal Pacific fuse panel. I don't have problems with the
> panel. But, it is a split bus panel. Should the panel be replaced if
> I am not having problems? It's a 200 amp panel.
>
> Thanks,
>
> Dan
>



Posted by =?iso-8859-15?Q?Tekkie=AE?= on September 18, 2006, 7:31 pm
TrailRunner posted for all of us...

> I have a Federal Pacific fuse panel. I don't have problems with the
> panel. But, it is a split bus panel. Should the panel be replaced if
> I am not having problems? It's a 200 amp panel.
>
> Thanks,
>
> Dan
>
>
Maybe
--
Tekkie "There's no such thing as a tool I don't need."

Posted by RBM on September 18, 2006, 8:41 pm
The problem with any split buss panel is that unless ONLY conscientious
professionals are doing work in it, it has the potential to overload the
main feeder


>I have a Federal Pacific fuse panel. I don't have problems with the
> panel. But, it is a split bus panel. Should the panel be replaced if
> I am not having problems? It's a 200 amp panel.
>
> Thanks,
>
> Dan
>



Posted by Eric in North TX on September 18, 2006, 9:06 pm

In my opinion if it says Federal Pacific on the cover it should be
replaced.


Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Federal Pacific breakers January 11, 2006, 2:02 am
"Federal Pacific" Breaker box November 7, 2006, 8:42 am
skinny Federal Pacific breakers April 1, 2008, 12:34 pm
Compatible Ckt Breakers For A LX112-24 Box by the Federal Pacific Electric Co. ? August 3, 2005, 7:50 pm
Federal Pacific Circuit Breaker Box with Challenger breakers??? February 20, 2007, 9:33 pm
Breakers compatible with Federal Pacific Stab-Lok Load Center April 16, 2008, 4:30 pm
Fuse box to CB Panel - logistics July 27, 2007, 11:34 am
Fuse Electrical Panel Cover July 17, 2006, 12:52 pm
Home Electrical Fuse Panel February 3, 2007, 6:28 am
diff between a 250V 10A fuse and a 32V 10A glass fuse? November 1, 2006, 12:57 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap