Few very basic Electrical questions

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 8       1 2 3 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Few very basic Electrical questions SMF 06-15-2006
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by SMF on June 15, 2006, 7:22 pm
Hi,

I bought a book plus spent a number of hours on the computer to
research and I hope someone can help me with just a few very basic
questions I still have:

1. I have a 100 amp service. If I turn off the main circuit breaker
can I change for instance a 20 amp breaker without worry of shock if I
don't touch anything else other than the breaker and the wire that
needs to be unscrewed? (I have a few that don't match my GE panel and
I heard that they should)

2. I had an electrician once run an extra outlet but in looking a few
years later I see that he ran 14/2 cable after attaching this to 12/2
running off a 20 amp breaker. This line either powers a treadmill
(runs on a "115 vac dedicated 20 amp {15 amp] circuit") or a iron.
The receptacle is 15amp which I believe is fine with either, but
should I swap the cable to 12/2 for safety?

3. I also have similar to question two above (14/2, connected to
12/2) going to a GPF in a garage that the same guy did. Do they make
a 20 amp GPF and should I switch the cable and the receptacle in this
instance too?

4. Can you run a series of five 15 amp receptacles for a workbench in
an unfinished basement running on 12/2 on a 20 amp GPF breaker?

I really appreciate all your help!!

Best Regards,
Steven                

PexSupply PEX Tools 468x60
Posted by Colbyt on June 15, 2006, 8:35 pm

> Hi,
>
> I bought a book plus spent a number of hours on the computer to
> research and I hope someone can help me with just a few very basic
> questions I still have:
>
> 1. I have a 100 amp service. If I turn off the main circuit breaker
> can I change for instance a 20 amp breaker without worry of shock if I
> don't touch anything else other than the breaker and the wire that
> needs to be unscrewed? (I have a few that don't match my GE panel and
> I heard that they should)
>
> 2. I had an electrician once run an extra outlet but in looking a few
> years later I see that he ran 14/2 cable after attaching this to 12/2
> running off a 20 amp breaker. This line either powers a treadmill
> (runs on a "115 vac dedicated 20 amp {15 amp] circuit") or a iron.
> The receptacle is 15amp which I believe is fine with either, but
> should I swap the cable to 12/2 for safety?
>
> 3. I also have similar to question two above (14/2, connected to
> 12/2) going to a GPF in a garage that the same guy did. Do they make
> a 20 amp GPF and should I switch the cable and the receptacle in this
> instance too?
>
> 4. Can you run a series of five 15 amp receptacles for a workbench in
> an unfinished basement running on 12/2 on a 20 amp GPF breaker?
>
> I really appreciate all your help!!
>
> Best Regards,
> Steven

No license here so I don't have to cya.

1. You should test it first with a simple tester but the normal answer is
that all the breakers and everything below the main breaker is safe to touch
with the main turned off. The juice stops inside the main breaker. The lugs
above the main breaker are still HOT.

2. I would because de-rating the wire is only allowed (or was allowed) when
there is no possibility that it could ever pull more than it was designed
for. Example: you wire a single light fixture with 14/2 at the end of a 20
amp circuit.

3. I think they do at a premium price. I would most likely change the wire
and leave the GFIC as it is.

4. 20 amp circuits by code require 20 amp devices. There really is no
defined limit to the number of devices. The 15 amp ones will most likely
work fine and be safe but they are not "to code". Would I use them? Yes
because in normal usage you are never going to pull 20 amps.

Your breakers must be rated and tested for the panel they are installed in
to meet code.You may want to check the breakers before you go to the trouble
to change them. They may be rated for your box. That said there are
millions of breakers in boxes all around the world that do not meet that
standard. The vast majority of them are perfectly safe and work as they
should.


Colbyt



Posted by Doug Miller on June 15, 2006, 10:19 pm

>4. 20 amp circuits by code require 20 amp devices. There really is no
>defined limit to the number of devices. The 15 amp ones will most likely
>work fine and be safe but they are not "to code".

Incorrect.

The NEC explicitly permits the use of 15A receptacles on a 20A circuit. See
Article 210.21(B)(3).

--
Regards,
Doug Miller (alphageek at milmac dot com)

It's time to throw all their damned tea in the harbor again.

Posted by Colbyt on June 16, 2006, 1:22 pm

>
>>4. 20 amp circuits by code require 20 amp devices. There really is no
>>defined limit to the number of devices. The 15 amp ones will most likely
>>work fine and be safe but they are not "to code".
>
> Incorrect.
>
> The NEC explicitly permits the use of 15A receptacles on a 20A circuit.
> See
> Article 210.21(B)(3).
>
> --
> Regards,
> Doug Miller (alphageek at milmac dot com)


Thanks for the info Doug. All these years I thought I was cheating. I
based my assumption on what I saw done in commercial installs. Some of that
stuff might have pulled 17 amps on startup so I guess that is why they went
with all 20's.


Colbyt



Posted by James \"Cubby\" Culbertson on June 15, 2006, 11:15 pm

>
> 4. 20 amp circuits by code require 20 amp devices. There really is no
> defined limit to the number of devices. The 15 amp ones will most likely
> work fine and be safe but they are not "to code". Would I use them? Yes
> because in normal usage you are never going to pull 20 amps.
>
I might add that you should check your "local" code as well. Mine for
instance limits the number
of devices (a receptacle being one device) on a single circuit to 10. As
well, 15A receptacles on a 20 A circuit are allowed by the NEC but
for the small difference in price, I'd just install the 20A recepts.
Cheers,
cc



Page 1 of 8       1 2 3 > last >>
Similar ThreadsPosted
Electrical Wiring Basic Questions September 3, 2007, 11:37 pm
BASIC oil burner questions February 18, 2006, 11:20 am
Basic framing questions June 10, 2008, 8:44 pm
basic electrical panel intuition August 25, 2005, 10:56 am
Basic Home Electrical Question October 22, 2005, 4:11 pm
Any good books/online resources for learning basic electrical skills? July 28, 2006, 4:56 pm
suggest basic func/signal generator for basic scope test/setup ? October 5, 2007, 11:08 am
basic - I mean basic washing machine repair January 30, 2006, 8:42 am
Electrical questions March 7, 2006, 1:56 pm
electrical questions November 14, 2006, 4:04 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap