Posted by daokfella on June 28, 2007, 10:08 am
I've been in my home almost 10 years and all of a sudden, a single
circuit in my home started to flicker and intermittently power on and
off (the breaker never tripped). I've done electrical work in the past
when I finished my basement. The first thing I thought of was to
replace the breaker. It's a Cutler Hammer twin (slimline) 15A breaker.

After replacing it, the problem still occurred (so it was unlikely it
was the breaker). After some diagnosising, I noticed that there was
some arching ocurring in one of the terminals on the neutral buss bar.
I tapped on the panel, and a small spark shot from the terminal. I
turned off the circuit in question, and the arching and spark ceased.
I then knew that the arching neutral belonged to the circuit in
question.

I found it odd that there are one or two ground wires on the neutral
buss bar. However, the neutral buss bar is right on top of the ground
buss bar. Don't they go to the same place anyway? Is this odd or OK? I
know I've seen some panels where the ground buss is totally separated
from the neutral buss.

This neutral wire is sharing the same screw terminal on the buss bar
with a ground wire from another circuit. I shut off the main breaker
and screwed down the terminal firmly which fixed the problem. However,
5 days later, it started happening again. No sparks fly when I tap on
the panel, but there is slight arching in that same termAinal.

Just eyeballing it, it looks like my neutral is a 14 gauge whilst the
ground in the same terminal might be a 12 gauge which would explain
why the neutral is not secured enough by the screw terminal. I am
going to to shut off the main breaker do some housekeeping on the
terminals making sure the same gauge wire is shared by neutrals in the
same terminal.

1. Does it look like I've diagnosed the problem and I'm taking the
correct measures to fix it?

2. Why would this happen all of sudden after 10 years of living in the
home? The terminal screw didn't seem all that loose when I tightened
it the first time. I barely got 1/16 to 1/8 of a turn on it.

3. Is it OK for neutrals and grounds to share the same terminal on the
neutral buss bar? Of different or same circuits?

4. Any other comments to add on what I've described?

Thanks,

Jason


Posted by Doug Miller on June 28, 2007, 10:35 am
>I've been in my home almost 10 years and all of a sudden, a single
>circuit in my home started to flicker and intermittently power on and
>off (the breaker never tripped). I've done electrical work in the past
>when I finished my basement. The first thing I thought of was to
>replace the breaker. It's a Cutler Hammer twin (slimline) 15A breaker.
>
>After replacing it, the problem still occurred (so it was unlikely it
>was the breaker). After some diagnosising, I noticed that there was
>some arching ocurring in one of the terminals on the neutral buss bar.
>I tapped on the panel, and a small spark shot from the terminal. I
>turned off the circuit in question, and the arching and spark ceased.
>I then knew that the arching neutral belonged to the circuit in
>question.

Sounds like that terminal is a bit loose. Did you tighten it?

And is this copper wire, or aluminum?
>
>I found it odd that there are one or two ground wires on the neutral
>buss bar. However, the neutral buss bar is right on top of the ground
>buss bar. Don't they go to the same place anyway? Is this odd or OK? I
>know I've seen some panels where the ground buss is totally separated
>from the neutral buss.

It's OK, as long as this is your main panel. Neutral and ground are required
to be connected at the service entrance (main) panel, and required to *not* be
connected anywhere else.

>This neutral wire is sharing the same screw terminal on the buss bar
>with a ground wire from another circuit.

That is *not* OK unless the terminals are specifically listed for use with
more than one wire. If they are, it will say so on the label inside the panel
access door.

>I shut off the main breaker
>and screwed down the terminal firmly which fixed the problem. However,
>5 days later, it started happening again. No sparks fly when I tap on
>the panel, but there is slight arching in that same termAinal.
>
>Just eyeballing it, it looks like my neutral is a 14 gauge whilst the
>ground in the same terminal might be a 12 gauge which would explain
>why the neutral is not secured enough by the screw terminal. I am
>going to to shut off the main breaker do some housekeeping on the
>terminals making sure the same gauge wire is shared by neutrals in the
>same terminal.

Better still to use only one wire per terminal.

>1. Does it look like I've diagnosed the problem and I'm taking the
>correct measures to fix it?

Diagnosed the problem, yes. Correct measures to fix it, probably not. The best
fix is one wire per terminal (unless the terminals are specifically listed for
two wires).
>
>2. Why would this happen all of sudden after 10 years of living in the
>home? The terminal screw didn't seem all that loose when I tightened
>it the first time. I barely got 1/16 to 1/8 of a turn on it.

Copper or aluminum wire? This is VERY important.
>
>3. Is it OK for neutrals and grounds to share the same terminal on the
>neutral buss bar? Of different or same circuits?

As long as we're talking about a main panel, not a subpanel, and the terminals
are listed for use with two or more wires, that's fine. Since the neutral and
ground are electrically continuous in the main panel, there's no problem
electrically. Mechanically, you may have a problem attaching multiple wires
securely.
>
>4. Any other comments to add on what I've described?

If this is aluminum wire, you have to be *very* careful not to overtighten the
connections.

--
Regards,
Doug Miller (alphageek at milmac dot com)

It's time to throw all their damned tea in the harbor again.

Posted by daokfella on June 28, 2007, 10:45 am
Thanks Doug,

This is copper wiring. I do notice on the buss bar that there are two
sizes of screw terminals. The ones containing two wires are of the
larger size. However, the point is taken. When I do my "housekeeping"
on the panel, I will try to keep it one wire per terminal. It does
look like, however, that there may not be enough terminals for each
circuit to be in it's own, but I'll get a closer look. The last time I
worked closely with the panel is when I installed a 50A breaker and
wired in a sub-panel for my finished basement.

It definitely seems like a poor connection on the buss since it worked
fine for a week after tightening it. However, this morning it was back
to flickering and arching.

Thanks for your help.


Posted by dpb on June 28, 2007, 10:58 am
daokfella wrote:
> Thanks Doug,
>
> This is copper wiring. I do notice on the buss bar that there are two
> sizes of screw terminals. The ones containing two wires are of the
> larger size. However, the point is taken. When I do my "housekeeping"
> on the panel, I will try to keep it one wire per terminal. It does
> look like, however, that there may not be enough terminals for each
> circuit to be in it's own, but I'll get a closer look. The last time I
> worked closely with the panel is when I installed a 50A breaker and
> wired in a sub-panel for my finished basement.
>
> It definitely seems like a poor connection on the buss since it worked
> fine for a week after tightening it. However, this morning it was back
> to flickering and arching.

That may be indication of other connections on the circuit having
similar problems, too (although I guess you're seeing arcing at that
same neutral in the box so that would definitely be a problem).

See my other response on cleaning terminals and wires to remove
corrosion/oxidation. If the wires have been flattened by previous
connection might snip off to a new end if have a little slack. Moving
one or more to alternate location on the neutral bar is a possibility
although shouldn't be necessary unless the arcing has significantly
damaged that connection location. It is likely that if there has been
sufficient arcing you have seen it that it has caused some oxidation of
the surfaces. If so, may not be making good contact even if you did
retighten connections.

Whatever, don't give up until resolve it as (I'm sure you're well aware)
this ain't good...

--

Posted by EXT on June 28, 2007, 11:02 am
If you have to put two wires into the same terminal, either try to keep the
wire gauge the same so that the pressure is the same on both wires, or twist
the wires together before inserting into the terminal, which may be
difficult to insert the twisted wires without them untwisting, but you will
get a much better connection with equal pressure on both wires.


> Thanks Doug,
>
> This is copper wiring. I do notice on the buss bar that there are two
> sizes of screw terminals. The ones containing two wires are of the
> larger size. However, the point is taken. When I do my "housekeeping"
> on the panel, I will try to keep it one wire per terminal. It does
> look like, however, that there may not be enough terminals for each
> circuit to be in it's own, but I'll get a closer look. The last time I
> worked closely with the panel is when I installed a 50A breaker and
> wired in a sub-panel for my finished basement.
>
> It definitely seems like a poor connection on the buss since it worked
> fine for a week after tightening it. However, this morning it was back
> to flickering and arching.
>
> Thanks for your help.
>



Page 1 of 3       1 2 3 > last >>
Similar ThreadsPosted
Lights flickering October 31, 2005, 9:56 pm
Flickering Lights April 5, 2006, 8:33 pm
fluorescent lights flickering June 4, 2006, 9:58 pm
Flickering/dimming lights January 9, 2007, 6:32 pm
Flickering Low Voltage Lights March 8, 2008, 10:19 pm
Flickering lights on one circuit April 11, 2008, 3:27 pm
How to add ground buss bar October 13, 2005, 8:24 am
Flickering florescents December 11, 2006, 10:16 am
Flickering Bulb Question December 11, 2006, 9:17 pm
security light flickering December 13, 2007, 8:17 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap