Furnace not starting all the time on the first try?

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Furnace not starting all the time on the first try? diyme 01-16-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by diyme on January 16, 2007, 11:03 am



furnace exhaust fan turns on... then the heating element lights up....
then the
gas ignites breafly and then gas shuts off..then the fan stays
on and it starts
the process all over until it lights. most of the time
it lights on the second
time.
It does not do this all the time but more then we like.
Why is this happening?? Can we fix this or do we need to call someone?
Goodman installed in late 1998.




--
diyme

Real Goods Solar, Inc.
Posted by Tony Hwang on January 16, 2007, 11:45 am


diyme wrote:
> furnace exhaust fan turns on... then the heating element lights up....
> then the gas ignites breafly and then gas shuts off..then the fan stays
> on and it starts the process all over until it lights. most of the time
> it lights on the second time.
> It does not do this all the time but more then we like.
> Why is this happening?? Can we fix this or do we need to call someone?
> Goodman installed in late 1998.
>
>
>
>
Hi,
Two things to check; flame sensor and inducer pressure switch.
Sensor can have a fine surface rust causing intermittent operation,
switch can have a debris in the hose.

Posted by blueman3333 on January 19, 2007, 9:58 am


> diyme wrote:
> > furnace exhaust fan turns on... then the heating element lights up....
> > then the gas ignites breafly and then gas shuts off..then the fan stays
> > on and it starts the process all over until it lights. most of the time
> > it lights on the second time.
> > It does not do this all the time but more then we like.
> > Why is this happening?? Can we fix this or do we need to call someone?
> > Goodman installed in late 1998.
> >
> Hi,
> Two things to check; flame sensor and inducer pressure switch.
> Sensor can have a fine surface rust causing intermittent operation,
> switch can have a debris in the hose.

I just went through a perhaps similar problem. Ended up being a problem with
the condensate drain lines. Combination of blockage in the line
leading from the ventor motor exhaust port to the trap and a slight
slope in the distal end of the condensate tubing just before it
entered the condensate pump. These combined to cause the inducer
pressure switch to shut off after condensate started
accumulating.

However, if problem is that the flame first shuts off almost
immediately but then burns properly for a sustained period the second
time, it probably is not a condensate blockage problem. Since
condensate blockage should build up more the longer the flame burns.

Posted by Cheri on January 16, 2007, 12:29 pm



diyme wrote in message ...
>
>furnace exhaust fan turns on... then the heating element lights up....
>then the gas ignites breafly and then gas shuts off..then the fan stays
>on and it starts the process all over until it lights. most of the time
>it lights on the second time.
>It does not do this all the time but more then we like.
>Why is this happening?? Can we fix this or do we need to call someone?
>Goodman installed in late 1998.

The tech told me yesterday that the fan would always run, even if the
burner doesn't stay lit. Sometimes with mine, the fan would run for an
hour or so, blowing cold air, before it would light and stay lit. I
would only know that happened when it started getting warm in the house.
I'm having mine fixed in the next couple of days when the parts come in,
so if I learn anything about my problem, I'll post it and maybe it will
help you.

Cheri



Posted by on January 16, 2007, 12:31 pm


I just went rhough this on my Amana furnace. Cleaning the flame sensor
did the trick and stopped it from going into lockout with the fan
running constantly.

Cheri wrote:
> diyme wrote in message ...
> >
> >furnace exhaust fan turns on... then the heating element lights up....
> >then the gas ignites breafly and then gas shuts off..then the fan stays
> >on and it starts the process all over until it lights. most of the time
> >it lights on the second time.
> >It does not do this all the time but more then we like.
> >Why is this happening?? Can we fix this or do we need to call someone?
> >Goodman installed in late 1998.
>
> The tech told me yesterday that the fan would always run, even if the
> burner doesn't stay lit. Sometimes with mine, the fan would run for an
> hour or so, blowing cold air, before it would light and stay lit. I
> would only know that happened when it started getting warm in the house.
> I'm having mine fixed in the next couple of days when the parts come in,
> so if I learn anything about my problem, I'll post it and maybe it will
> help you.
>
> Cheri


Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
Furnace Blower has hard time starting June 9, 2008, 2:06 pm
Furnace low heat run time = A/C low cool run time December 29, 2005, 4:42 am
gas forced air furnace not starting in AM November 11, 2005, 8:23 am
Time for a new furnace? September 21, 2005, 10:08 pm
Oil Furnace Not Coming On All The Time December 8, 2006, 1:17 am
Time to buy a new furnace. Advice neeeded. December 12, 2006, 8:47 pm
Furnace igniter clicking all the time December 28, 2007, 4:00 pm
Furnace running at high for a long time December 28, 2005, 2:32 pm
Re: York Heat Pump and furnace both run at the same time..is this normal? November 15, 2007, 5:29 pm
Re: York Heat Pump and furnace both run at the same time..is this normal? November 15, 2007, 1:44 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap