Home Page link

GFI for whirlpool tub

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Page 1 of 2       1 2 > last >> Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
GFI for whirlpool tub trexxxmeister 01-29-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by on January 29, 2008, 12:01 am
I am installing a whirlpool bathtub.The instructions say I have to
plug the pump into a 15a 110v seperate circuit protected with GFCI,
and the heater into a 15a 110v seperate circuit protected with gfci.I
take it I have to run wires to my main service box.I notice that gfci
circuit breakers are very expensive.Can I just install regular circuit
breakers and hook them up to gfci sockets by my bathtub.
Thanks

Electric Radiant Heat 468x60
Posted by Tony Hwang on January 29, 2008, 12:19 am
trexxxmeister@gmail.com wrote:
> I am installing a whirlpool bathtub.The instructions say I have to
> plug the pump into a 15a 110v seperate circuit protected with GFCI,
> and the heater into a 15a 110v seperate circuit protected with gfci.I
> take it I have to run wires to my main service box.I notice that gfci
> circuit breakers are very expensive.Can I just install regular circuit
> breakers and hook them up to gfci sockets by my bathtub.
> Thanks

Hi,
There is a GFCI 15A circuit breker for that. Our tub is wired with it.
It is regular breaker like but with a tab which pops when there is
trouble in the circuit.

Posted by SteveB on January 29, 2008, 2:14 am

>I am installing a whirlpool bathtub.The instructions say I have to
> plug the pump into a 15a 110v seperate circuit protected with GFCI,
> and the heater into a 15a 110v seperate circuit protected with gfci.I
> take it I have to run wires to my main service box.I notice that gfci
> circuit breakers are very expensive.Can I just install regular circuit
> breakers and hook them up to gfci sockets by my bathtub.
> Thanks

Won't pass inspection, although you may not have it inspected if you DIY.
But it is an item that a house inspector would spot in a second if you go to
sell the house. And if there's ever a short without a GFI, the house may be
up for sale by the heirs.

Steve



Posted by hobbes on January 29, 2008, 6:55 am
>
>
> >I am installing a whirlpool bathtub.The instructions say I have to
> > plug the pump into a 15a 110v seperate circuit protected with GFCI,
> > and the heater into a 15a 110v seperate circuit protected with gfci.I
> > take it I have to run wires to my main service box.I notice that gfci
> > circuit breakers are very expensive.Can I just install regular circuit
> > breakers and hook them up to gfci sockets by my bathtub.
> > Thanks
>
> Won't pass inspection, although you may not have it inspected if you DIY.
> But it is an item that a house inspector would spot in a second if you go =
to
> sell the house. =A0And if there's ever a short without a GFI, the house ma=
y be
> up for sale by the heirs.
>
> Steve

Hi,

I think that what Mr. Trexxxmeis wanted to know is if he could use a
GFCI socket instead of a GFCI breaker because a GFCI breakers are
expensive.

I am not an expert in NEC code but I think that a GFCI breaker is
better in the respect that the GFCI's protection is outside the
bathroom away from water. Consider the following scenario. If water
from the bathtub were to get behing the GFCI socket which is in the
bathroom, this effectively eliminates the GFCI protection. The GFCI
breaker being in a different area of the house is of course not
exposed to this risk.

I suppose that GFCI socket could be used so long as that socket is
outside the bathroom and no water could get behind the GFCI. However
this now allows other appliances to be pluged into the same circuit as
the Whirlpool tub. This then breaks the "dedicated circuit rule." I
suppose you do not want to overload that 15 amp circuit for the
whirlpool heater.

Just my 2 cents.

best, Mike.

Posted by RBM on January 29, 2008, 7:10 am
Yes you can. Run the two circuits to the location under the tub where the
support equipment is located and install a large deep two gang box with two
GFCI outlets in it , one for the pump and one for the heater





>I am installing a whirlpool bathtub.The instructions say I have to
> plug the pump into a 15a 110v seperate circuit protected with GFCI,
> and the heater into a 15a 110v seperate circuit protected with gfci.I
> take it I have to run wires to my main service box.I notice that gfci
> circuit breakers are very expensive.Can I just install regular circuit
> breakers and hook them up to gfci sockets by my bathtub.
> Thanks



Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
whirlpool December 27, 2005, 6:58 pm
whirlpool December 27, 2005, 6:58 pm
Maytag now Whirlpool August 23, 2005, 6:57 am
Help with Whirlpool tub - cleaning December 14, 2005, 12:23 am
Whirlpool Range December 21, 2005, 9:45 pm
Whirlpool Gas Dryer January 30, 2006, 11:01 pm
Whirlpool Range March 5, 2006, 7:08 pm
whirlpool gas dryer September 2, 2006, 3:07 pm
Whirlpool Washer? September 3, 2006, 7:05 pm
Whirlpool tub motor December 10, 2006, 4:33 pm