Posted by on June 15, 2006, 1:51 am
My pool heater is acting up this year. Once the pilot is lit, it stays
lit. The thermostat works, in that I can hear it click as it is
rotated past a certain point, and my meter shows that it is opening and
closing with the click. The vast majority of the time, rotating the
thermostat to the point of calling for heat, does NOT fire the burner.
If I jumper the TH terminals, and get the burner started, then the
thermostat usually takes over and lets the burner cycle off and on.
But if the thermostat quits firing the burner, I have to jumper it
again. Since the thermostat is wired to the pressure safety switch, I
was thinking that maybe the pressure safety switch was going bad, but
that is just a guess. Before I start replacing parts, I thought I's
post here.

Can someone point me in the right direction? I'd appreciate any
help/info.

Tim


Special 468x60
Posted by Richard J Kinch on June 15, 2006, 3:15 am
> Can someone point me in the right direction?

Checked the thermocouple?

Posted by on June 15, 2006, 3:37 am

Richard J Kinch wrote:
> > Can someone point me in the right direction?
>
> Checked the thermocouple?

I figured that the thermocouple was good, since it was letting the
pilot stay lit, and would sometimes let gas flow. How can I test it -
heat it up and see if it's voltage output changes?


Posted by Richard J Kinch on June 15, 2006, 7:32 pm
> How can I test it -
> heat it up and see if it's voltage output changes?

Easiest to have a spare and swap it in. Thermocouples are hard to meter
for performance.

Posted by RBM on June 15, 2006, 6:57 am
You may have a stuck main gas valve. Is the valve 24 volt or millivolt?


> My pool heater is acting up this year. Once the pilot is lit, it stays
> lit. The thermostat works, in that I can hear it click as it is
> rotated past a certain point, and my meter shows that it is opening and
> closing with the click. The vast majority of the time, rotating the
> thermostat to the point of calling for heat, does NOT fire the burner.
> If I jumper the TH terminals, and get the burner started, then the
> thermostat usually takes over and lets the burner cycle off and on.
> But if the thermostat quits firing the burner, I have to jumper it
> again. Since the thermostat is wired to the pressure safety switch, I
> was thinking that maybe the pressure safety switch was going bad, but
> that is just a guess. Before I start replacing parts, I thought I's
> post here.
>
> Can someone point me in the right direction? I'd appreciate any
> help/info.
>
> Tim
>



Page 1 of 2       1 2 > last >>
Similar ThreadsPosted
oil hot water heater--WANT TO CONVERT to pool heater January 4, 2008, 7:32 pm
Re: pool questions June 12, 2005, 10:43 pm
Pool Solar Questions July 17, 2005, 11:50 am
swimming pool questions June 25, 2005, 11:32 am
DE Pool Filter Questions June 5, 2006, 4:01 pm
Pool Chlorine questions June 8, 2006, 11:35 am
Pool cover questions January 4, 2007, 7:54 am
Pool cover questions January 22, 2007, 7:33 am
Re: Swimming Pool Pump - 2 Questions May 6, 2006, 5:02 pm
Swimming pool filter questions May 23, 2006, 11:00 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap