Posted by lana.dangthomsen@gmail.com on February 17, 2007, 3:31 pm


Hi, I don't know that much about home repair in general. I am having
some work done, and I want to know if it is done correctly or not.

I am having a heating vent installed in a new finished office. He is
using metal duct, but he is only taping it closed and together. It is
heat tape with red print on it but he is not using any screws. I
question him about this because all of my other duct work uses screws,
but he tells me that using tape is better better because it prevents
all leaks? My question is, if this is really the right way to do it?

And my oven hood vent, we originally agreed to create a new vent for
it through my vaulted ceiling, then he said we could go through the
wall, and then through my unheated attic. I was fine with that, but
upon further investigation, I found out he connected it to my bathroom
4" bathroom duct. I talked to him, and he will change it to have
it's own duct. He also used an insulated flexible duct, when I did
research, I found it stated that you should use hard metal duct. He
said it was better to use flexible insulated duct so you don't get
return cold air? Is this right, or should I ask for rigid metal
duct?

Can you just glue and screw plywood to a cement basement or do you
need a moisure barrier between the plywood and cement? He is doing
this to raise the level of my office to the same level as the tile in
my hallway so I can float engineer hardwood on it.

Just want to make sure I am getting my home improvement done
correctly. Thanks,

Lulu


Real Goods Solar, Inc.
Posted by Joseph Meehan on February 17, 2007, 6:53 pm


lana.dangthomsen@gmail.com wrote:
> Hi, I don't know that much about home repair in general. I am having
> some work done, and I want to know if it is done correctly or not.
>
> I am having a heating vent installed in a new finished office. He is
> using metal duct, but he is only taping it closed and together. It is
> heat tape with red print on it but he is not using any screws. I
> question him about this because all of my other duct work uses screws,
> but he tells me that using tape is better better because it prevents
> all leaks? My question is, if this is really the right way to do it?

Normally for air ducts I use both. I would guess, that if the ducts
were otherwise secure without the tape, that should be enough. If not, I
would want both.

>
> And my oven hood vent, we originally agreed to create a new vent for
> it through my vaulted ceiling, then he said we could go through the
> wall, and then through my unheated attic. I was fine with that, but
> upon further investigation, I found out he connected it to my bathroom
> 4" bathroom duct. I talked to him, and he will change it to have
> it's own duct. He also used an insulated flexible duct, when I did
> research, I found it stated that you should use hard metal duct. He
> said it was better to use flexible insulated duct so you don't get
> return cold air? Is this right, or should I ask for rigid metal
> duct?

You got a real winner there. Rigid only!


>
> Can you just glue and screw plywood to a cement basement or do you
> need a moisure barrier between the plywood and cement? He is doing
> this to raise the level of my office to the same level as the tile in
> my hallway so I can float engineer hardwood on it.

Ill bet the flooring company will specify a vapor barrier. I would
demand one.

>
> Just want to make sure I am getting my home improvement done
> correctly. Thanks,
>
> Lulu

--
Joseph Meehan

Dia 's Muire duit




Posted by Cabinets Galore on February 17, 2007, 7:01 pm



| Hi, I don't know that much about home repair in general. I am having
| some work done, and I want to know if it is done correctly or not.
|
| I am having a heating vent installed in a new finished office. He is
| using metal duct, but he is only taping it closed and together. It is
| heat tape with red print on it but he is not using any screws. I
| question him about this because all of my other duct work uses screws,
| but he tells me that using tape is better better because it prevents
| all leaks? My question is, if this is really the right way to do it?


no it is not the correct way
the round ducts should have 3 screws in them.
rectangular ducts should have 4 screws.
then sealed with duct seal NOT heat tape.
heat tape is for the insulation that goes over the ducting.





|
| And my oven hood vent, we originally agreed to create a new vent for
| it through my vaulted ceiling, then he said we could go through the
| wall, and then through my unheated attic. I was fine with that, but
| upon further investigation, I found out he connected it to my bathroom
| 4" bathroom duct. I talked to him, and he will change it to have
| it's own duct. He also used an insulated flexible duct, when I did
| research, I found it stated that you should use hard metal duct.



stainless steel ducting is best for grease from a hood.
never use plastic or vinyl ducting for a hood.
the shorter the distance of the ducting, the more efficient it will be.





He
| said it was better to use flexible insulated duct so you don't get
| return cold air?

He is an ass
or you are a troll
which is it?
an in-line damper is installed for back drafts





Is this right, or should I ask for rigid metal
| duct?

stainless steel ducting is best for grease from a hood.
never use plastic or vinyl ducting for a hood.
insist on metal.




|
| Can you just glue and screw plywood to a cement basement or do you
| need a moisure barrier between the plywood and cement?

plywood on a cement floor?
why bother?
install the new floor directly over the concrete with thicker padding
for comfort..
vapor barrier over concrete - absolutely not





He is doing
| this to raise the level of my office to the same level as the tile in
| my hallway so I can float engineer hardwood on it.
|
| Just want to make sure I am getting my home improvement done
| correctly. Thanks,

sounds like you really picked a winner to do the work for you.
good luck with this project
(I mean, your contractor sounds like a science project)


|
| Lulu
|



Similar ThreadsPosted
duck tape on dryer heat vent? March 28, 2007, 12:52 am
stove hood vent question March 5, 2007, 1:18 pm
Range hood vent options/ self venting or vent through roof ? September 2, 2007, 10:35 am
Noisy vent hood July 30, 2005, 1:46 am
Attic fan for vent a hood October 25, 2005, 12:35 am
Duct Tape, or what? December 10, 2005, 3:42 pm
Should have used duct tape :( December 19, 2006, 3:50 pm
Stove Hood Vent Odor October 22, 2005, 4:00 pm
No vent hood over island range? December 6, 2005, 6:42 pm
Looking for a range hood with an offset vent May 31, 2006, 10:36 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap