Posted by on June 23, 2007, 9:28 pm
Hi,
I was trying to move a Bryant thermonstat to a different part of the
wall and everything went well except when I reconnected the wires and
closed the thermostat the thermostat did not turn on. It is the first
thermostat found here: http://www.thermostatusa.com/BryantResidential.asp
I had not turned of the A/C unit off when I was doing this and I saw a
couple sparks when the wires touched. I was wondering whether I may
have popped a breaker, but all breakers seem to be intact. All lights
everywhere in the house are on. There's a wetness tester next to the A/
C unit and the green "on" light is not on - I don't know whether it
was on before.'
I would appreciate any suggestions. Are there tests that I can perform
to identify what's not working?
Many thanks in advance,
Aaron
|
|
Posted by on June 23, 2007, 9:48 pm
if you have a circuit board in your ac/furnace. it may have blew a
circuit. it will look like a burn place on the cuircuit board.
http://www.minibite.com/america/malone.htm
|
|
Posted by Big_Jake on June 23, 2007, 10:17 pm
On Jun 23, 8:48 pm, d...@webtv.net wrote:
> if you have a circuit board in your ac/furnace. it may have blew a
> circuit. it will look like a burn place on the cuircuit board.
>
> http://www.minibite.com/america/malone.htm
I'm thinking the same, but more accurately, it is a 3A fuse. Your
furnace might have even come with a spare. Otherwise you might be
able to get one at an auto parts store or maybe Radio Shack. Don't
put in a bigger one!
JK
|
|
Posted by mm on June 23, 2007, 11:06 pm
On Sat, 23 Jun 2007 19:17:41 -0700, Big_Jake
>On Jun 23, 8:48 pm, d...@webtv.net wrote:
>> if you have a circuit board in your ac/furnace. it may have blew a
>> circuit. it will look like a burn place on the cuircuit board.
>>
>> http://www.minibite.com/america/malone.htm
>
>I'm thinking the same, but more accurately, it is a 3A fuse. Your
>furnace might have even come with a spare. Otherwise you might be
>able to get one at an auto parts store or maybe Radio Shack. Don't
>put in a bigger one!
House breakers are much much bigger than the amount of current used
internally to control things. For that there are glass fuses, or
maybe some other kind of small fuse.
When this happened when I was working on my friend's, there was a
spare fuse taped close to where the original fuse went. You dind't
give the brand of your AC, only the thermostat. It's the AC that
determines the fuse size, and when you find where the fuse goes,
somewhere near there it will say what size fuse to use. Perhaps on a
diagram, or on the circuit board, certainly someplace in the AC and
certainly also in the owners manual that came with the AC. IN my
friend's case, he had half of the AC ownners manual in his files, and
there was a second half stuffed in the condensor cabinet outside, that
the installer never took out and gave him. (Is that typical? They
leave it there for the repairmen?) I think both halves said what size
fuse to use, and one or both halves had a drawing that indicated where
the fuse went.
In that case, I blew the fuse by letting the control wires to the
condensor outside touch each other, but if you got sparks at the
thermostat, they are probably smart enough to make it blow a fuse,
probably the same fuse.
Next time, turn it off before moving wires, OK? And turn it off
before you replace the fuse, too. If not, you won't kill yourself, (I
don't think. :) ) but you might blow the second one.
>JK
|
|
Posted by mm on June 24, 2007, 1:31 am
wrote:
> it will say what size fuse to use. Perhaps on a
>diagram, or on the circuit board, certainly someplace in the AC and
>certainly also in the owners manual that came with the AC.
And of course, on the blown fuse itself, it will say what size it is.
There are several letters and numbers but it will say 3A if it is 3
amps.
|
Page 1 of 2 1 2 > last >>
| Similar Threads | Posted | | Thermostat install problem | October 27, 2005, 3:14 pm |
| Totaline thermostat problem | November 16, 2005, 1:08 pm |
| Honeywell Thermostat Problem | December 3, 2005, 1:04 pm |
| Problem with digital thermostat | March 19, 2006, 2:41 am |
| Need help with wireless thermostat problem | March 3, 2007, 7:02 pm |
| Water heater thermostat problem | May 22, 2007, 8:58 am |
| Carrier Infinity Control thermostat problem | December 15, 2005, 8:52 am |
| Honeywell Thermostat Chronotherm IV Plus Battery Problem | May 6, 2006, 11:19 pm |
| Carrier Infinity Control Thermostat Problem (I think) | July 3, 2006, 1:05 pm |
| Problem after replacing THERMOSTAT with a MARCONE part | January 25, 2008, 10:22 am |
|
|