Posted by on August 8, 2005, 8:40 pm


I'm trying to buy new programmable thermostats for my electic
baseboards.
Problem is, existing (mechanical Honeywell line) thermostats are rated
22amps but most of the programmable ones I see are rated around 16-20
amps.

Did someone just install some overkill thermostats or do I really need
ones rated at 22amps?

I tried researching heaters that I have but couldn't find any info.



Posted by Edwin Pawlowski on August 9, 2005, 10:17 am



> I'm trying to buy new programmable thermostats for my electic
> baseboards.
> Problem is, existing (mechanical Honeywell line) thermostats are rated
> 22amps but most of the programmable ones I see are rated around 16-20
> amps.
>
> Did someone just install some overkill thermostats or do I really need
> ones rated at 22amps?
>
> I tried researching heaters that I have but couldn't find any info.
>

How many watts are your heaters?
W ÷ V = A




Posted by PipeDown on August 9, 2005, 7:29 pm



> I'm trying to buy new programmable thermostats for my electic
> baseboards.
> Problem is, existing (mechanical Honeywell line) thermostats are rated
> 22amps but most of the programmable ones I see are rated around 16-20
> amps.
>
> Did someone just install some overkill thermostats or do I really need
> ones rated at 22amps?
>
> I tried researching heaters that I have but couldn't find any info.
>
If these thermostats actually switch the heater then you will need that much
current. Since most 110V AC branch circuits are rated for 20A max the
extra 2 amps is overhead.

If the thermostat switches a remote relay in the heater (as in most central
heating systems) then the extra current is way overkill as the thermostat is
most likly switching 12V and less than 1A




Posted by on August 9, 2005, 12:50 pm


That I'm not sure.
It's an electric baseboard, the thermostat is a single pole, 240v. It's
pretty much just spliced into the line going to the heater.

Each baseboard has its own thermostat.



Posted by PipeDown on August 9, 2005, 11:32 pm



> That I'm not sure.
> It's an electric baseboard, the thermostat is a single pole, 240v. It's
> pretty much just spliced into the line going to the heater.
>
> Each baseboard has its own thermostat.
>

Having a switch with a higher current rating is never a problem. There is
probably no difference in cost either. Since the heaters are directly
wired, and having 220V, 20A switch, you can have a heater up to 4800 watts.




Similar ThreadsPosted
Re: 15 amps or 20 amps April 12, 2007, 9:19 am
Re: 15 amps or 20 amps March 17, 2007, 12:25 am
Re: 15 amps or 20 amps March 17, 2007, 12:04 am
Re: 15 amps or 20 amps March 16, 2007, 11:11 pm
Re: 15 amps or 20 amps March 17, 2007, 1:55 am
Re: 15 amps or 20 amps March 17, 2007, 5:20 am
Re: 15 amps or 20 amps March 17, 2007, 6:54 am
Re: 15 amps or 20 amps March 18, 2007, 1:21 am
Re: 15 amps or 20 amps March 17, 2007, 10:06 am
Re: 15 amps or 20 amps March 17, 2007, 11:22 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap