Posted by Power's Mechanical on October 18, 2006, 7:33 pm
Don Wiss wrote:
> I have a couple of Panasonic window air conditioners that I have stored for
> several years with the front panels facing upwards. I switched to central
> air a few years ago and I'm trying to get rid of them. I found one fellow
> interested, but he and his brother claim that the way I have stored them
> has caused irreparable damage. Something about the refrigerant eating
> through the tubing and could cause leaking. This is new info to me! The
> units are about six years old, and are the ones with the electronic
> controls in the CW-XC series.
>
> Is there any basis to their claim?
>
> Don <www.donwiss.com> (e-mail link at home page bottom).
To answer your question, no the refrigerant will not eat throught the
lines. What can happen though is depending on the location of the
compressor suction and discharge lines, oil can drain out of the
compressor and into the system. That can be a bad thing.
|