Posted by Laura R on November 11, 2006, 2:04 am


Hi there,

My apartment complex was built in the late 50's, and has for the most
part the original appliances in each unit. (They're actually quite
charming. Push-button electric ranges!) My question concerns the
natural gas heater that I've got.

The model is a "Custom-Aire vented recessed wall heater" that is
installed in the wall between a room and a hallway. It uses natural
gas, and the pilot and ignition work fine. The problem as I see it
seems to be that it may have had a fan or blower attached at some
point, and if so it isn't working any more. Signs pointing to this are
the fact that the wall above the heater on one side seems to creak when
the heater goes on, and there's a crack in the plaster where the wall
gets *very* warm. I think if there was a blower or something, the air
would be circulating fast enough to prevent this, though I could be
wrong.

At this point, anything within the upper metal grills/housing is a
mystery. I got the bottom grill panel off and looked inside the bottom
half of the heater, but I don't have a clue as to what some of the
stuff does. There's an obvious gas pipe with a valve, the pilot pipe
with a separate valve, two large cones that I'm guessing are for
adjusting the air/gas mixture, wires leading to the thermostat (which
seems to be only half-functioning, but that's another story entirely)
and a black sort of brick with wires going to it. Does anyone have any
ideas on what's normal to see in a heater of this age? Diagrams would
be especially helpful.

Thanks!
-Laura


Posted by buffalobill on November 11, 2006, 3:58 am


turn unit off. get repaired.
maybe high limit sensor not working? if it is electrical it may be
connected to the heat exchanger in the upper area. if it is a millivolt
heater it may be a long copper capillary bulb that connects to the gas
valve.
blower may be optional?
also check your carbon monoxide alarm it will sometimes tell you when
the heat exchanger is cracked.

Laura R wrote:
> Hi there,
>
> My apartment complex was built in the late 50's, and has for the most
> part the original appliances in each unit. (They're actually quite
> charming. Push-button electric ranges!) My question concerns the
> natural gas heater that I've got.
>
> The model is a "Custom-Aire vented recessed wall heater" that is
> installed in the wall between a room and a hallway. It uses natural
> gas, and the pilot and ignition work fine. The problem as I see it
> seems to be that it may have had a fan or blower attached at some
> point, and if so it isn't working any more. Signs pointing to this are
> the fact that the wall above the heater on one side seems to creak when
> the heater goes on, and there's a crack in the plaster where the wall
> gets *very* warm. I think if there was a blower or something, the air
> would be circulating fast enough to prevent this, though I could be
> wrong.
>
> At this point, anything within the upper metal grills/housing is a
> mystery. I got the bottom grill panel off and looked inside the bottom
> half of the heater, but I don't have a clue as to what some of the
> stuff does. There's an obvious gas pipe with a valve, the pilot pipe
> with a separate valve, two large cones that I'm guessing are for
> adjusting the air/gas mixture, wires leading to the thermostat (which
> seems to be only half-functioning, but that's another story entirely)
> and a black sort of brick with wires going to it. Does anyone have any
> ideas on what's normal to see in a heater of this age? Diagrams would
> be especially helpful.
>
> Thanks!
> -Laura


Posted by Mikepier on November 11, 2006, 7:32 am


I'm surprised the unit fires up without the blower ( if there is
supposed to be one) because most of those vented wall funaces have a
sail switch that senses if the the blower is running. If it senses the
blower is not running, it will never fire up, unless someone bypassed
the switch.
I agree with the other poster, have a qualified tech look at it.


Posted by Lawrence on November 11, 2006, 9:53 am



Laura R wrote:
> Hi there,
>
> My apartment complex was built in the late 50's, and has for the most
> part the original appliances in each unit. (They're actually quite
> charming. Push-button electric ranges!) My question concerns the
> natural gas heater that I've got.

Since you are in apartment you might be able to inspect the heater of
another resident to see it there is any difference. I doubt if there is
a blower unit on your heater. I agree with the other poster that the
unit should be checked. Call the landlord and tell him you are worried
about the heater. Ask him if there is supposed to be a blower or if
the wall should be so hot. Heaters have improved a lot over the years.
You might be able to get a new one.


Similar ThreadsPosted
Recessed Wall Heaters November 11, 2005, 11:05 am
WTB door knob catch recessed in wall August 13, 2006, 10:53 am
Unvented heater/ODS info October 10, 2006, 5:51 am
Important COSTLY Info about that new water heater November 28, 2005, 9:25 pm
Gas Wall Heater January 9, 2006, 6:17 pm
Wall gas heater wasteful November 30, 2006, 10:32 pm
Any Experts Out there - Wall Heater Prob January 8, 2007, 6:13 pm
Baseboard heater Causes Dirty Wall? December 24, 2007, 12:57 pm
How clean wall heater vents? April 14, 2008, 2:06 am
Vintage IDEA's??? February 7, 2006, 2:52 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap