Intermittent heat problem with Rheem electric furnace

Home Repair - - If it ain't broken, don't fix it. Otherwise look here. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
Intermittent heat problem with Rheem electric furnace steph_beer_me 04-15-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by on April 15, 2007, 4:53 pm


I'm having an intermittent problem with my 7 year old Rheem electric
(forced air) furnace. About 2-3 random times a week the furnace will
fail to turn on despite the room temperature being below the
thermostat set value. To get it to function normally, I turn the
furnace off (at the thermostat), wait a few seconds, and turn it back
on. The furnace will then return to normal function from anywhere
from 12 to 72 hours, then it'll happen again.

Other interesting notes. When the furnace is 'malfunctioning' I have
seen the heating coils on, but not the fan (this obviously should
never happen). My immediate thought was that the blower motor was
going bad. The problem with this theory is that the blower always
comes on when I turn the fan on at the thermostat. So it appears to
me that the thermostat is either not sending the command to turn the
blower on (but is telling it to turn the heating elements) or that the
furnace is unable to always get the motor going. The thermostat is
digital (White-Rodgers) so it seems unlikely that it would work
intermittently.

Oh and I did replace the motor start capacitor because it was cheap
and easy. It didn't help.

I am stumped. Anyone have a clue here?


Posted by RBM on April 15, 2007, 5:20 pm


I don't know anything about this type of furnace, but I'd like to take a
stab at what it may be. I would think it normal for the heating elements to
come on without the blower. I would think there would be a sensor in the
heating chamber that turns on the fan at a set temperature, and off at
another set temperature. I would believe this or another sensor would also
turn off the elements if the blower didn't come on and the heating chamber
reached a set high limit. Because this is an electric furnace, this sensor
would have to be acting through a contactor for at least the heat part,
possibly the blower as well. If there is something wrong with this sensor,
it may be causing the safety control to go into a lockout mode



> I'm having an intermittent problem with my 7 year old Rheem electric
> (forced air) furnace. About 2-3 random times a week the furnace will
> fail to turn on despite the room temperature being below the
> thermostat set value. To get it to function normally, I turn the
> furnace off (at the thermostat), wait a few seconds, and turn it back
> on. The furnace will then return to normal function from anywhere
> from 12 to 72 hours, then it'll happen again.
>
> Other interesting notes. When the furnace is 'malfunctioning' I have
> seen the heating coils on, but not the fan (this obviously should
> never happen). My immediate thought was that the blower motor was
> going bad. The problem with this theory is that the blower always
> comes on when I turn the fan on at the thermostat. So it appears to
> me that the thermostat is either not sending the command to turn the
> blower on (but is telling it to turn the heating elements) or that the
> furnace is unable to always get the motor going. The thermostat is
> digital (White-Rodgers) so it seems unlikely that it would work
> intermittently.
>
> Oh and I did replace the motor start capacitor because it was cheap
> and easy. It didn't help.
>
> I am stumped. Anyone have a clue here?
>



Similar ThreadsPosted
Furnace blows but does not heat (intermittent problem) January 15, 2007, 8:19 pm
Whirlpool electric dryer; problem with heat/thermal cut-offs (no heat) August 31, 2007, 12:58 pm
No Heat (won't ignite gas) Rheem Criterion II January 5, 2006, 10:00 pm
No Heat (won't ignite gas) Rheem Criterion II January 5, 2006, 9:42 pm
Amana vs Rheem Heat Pump January 13, 2006, 7:54 pm
Goodman or Rheem gas furnace? October 5, 2005, 1:50 am
Rheem Classic 90 Plus furnace February 16, 2007, 10:49 am
Rheem Furnace stuck in on off cycle November 27, 2005, 3:16 pm
Intermittent problem with Goodman GMP075-3 February 14, 2005, 3:00 pm
Rheem Hot Water Heater Problem (toc246@gmail.com) April 16, 2007, 9:45 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap