A contractor is finishing my basement. I noticed that the electrician
put a recessed light fixture touching the PVC sewage pipe in the
ceiling.

Can the heat generated by the light damage the PVC pipe? (The recessed
light fixture is IC-rated if it matters).

Thanks


Tankless Water Heaters 468x60
Posted by RBM on August 28, 2007, 8:06 pm
If it's IC rated I wouldn't be concerned


>A contractor is finishing my basement. I noticed that the electrician
> put a recessed light fixture touching the PVC sewage pipe in the
> ceiling.
>
> Can the heat generated by the light damage the PVC pipe? (The recessed
> light fixture is IC-rated if it matters).
>
> Thanks
>



Posted by RickH on August 28, 2007, 8:10 pm
On Aug 28, 6:40 pm, hmm...@hotmail.com wrote:
> A contractor is finishing my basement. I noticed that the electrician
> put a recessed light fixture touching the PVC sewage pipe in the
> ceiling.
>
> Can the heat generated by the light damage the PVC pipe? (The recessed
> light fixture is IC-rated if it matters).
>
> Thanks

It should be ok, cans have a bimetal heat cutoff switch if they get to
194 degerees then back on at 184 degrees. And IC cans are made to run
cooler on the outside. If your lights flash (due to thermal switch
oscillating) then just go down 20 watts or so with the bulb, or drop
the bulb position down in the can (see wing nut). If the can against
the pipe is not also embedded in insulation it should run cool. I
have one in contact with some cat5 phone wiring and never had a
problem, and I'm sure cat5 has a lower melting point than PVC.



Similar ThreadsPosted
Leak in PVC pipe right where it touches my slab August 29, 2005, 6:55 am
Recessed light problem July 12, 2005, 1:21 am
Recessed light problem May 5, 2007, 7:33 am
installing new light fixture problem December 24, 2007, 5:51 pm
Light Switch & Fixture Problem January 25, 2008, 1:42 am
New recessed fixture is smoking February 24, 2008, 8:30 pm
Installing recessed lighting fixture in suspended ceiling January 28, 2006, 7:27 pm
converting kitchen fluorescent light to recessed light July 19, 2008, 5:40 pm
Can or Recessed light to Pendant light Conversion July 9, 2008, 10:14 am
Is 6" recessed light actually 6"? February 20, 2008, 10:04 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap