Posted by Speedy Jim on December 19, 2006, 9:21 am
crt765 wrote:
> Overnight there has been a noticeable loss of water pressure from the hot
> water heater. All faucets in the house are affected. There was not a
> gradual drop over several days. I believe the hot water heater is
> approxiately 5-6 years old. I was considering draining it to see if it
> was a sediment issue. I know it has not been drained in at least 4 years,
> which is how long we have been in our house. Will this help?
Sediment wouldn't normally build up a pile so high as
to block entry/exit. But worth a try as diagnostic.
See if the heater inlet/outlet connections are
equipped with "heat traps". Shiney nipple,
maybe 3-4" long. Looks exactly like a
"dielectric" nipple but has a tiny ball check inside.
http://news.thomasnet.com/fullstory/457271/954
Maybe a dip tube collapse, but that seems far-fetched.
Jim
|