Maximum Distance of Toilet from Vertical Stack? Johnny V 06-17-2008
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Johnny V on June 17, 2008, 12:52 pm
Hello Group,

I'm working for a friend on a gut job rehab, and his architect seems
inclined to provide plans with no mechanical details and no place to
put waste stacks.

In the interest of planning the job, I'm wondering, Can a Toilet, (as
part of a bath, including shower and lavatory, or half bath including
only lavatory), be attached to a Horizontal branch of a waste stack?
I've only ever seen them attached to the vertical sections of the
stack. If so, what restrictions are there on the length of the
Horizontal branch.

I've been reading the 2006 National Plumbing Code, and I can't seem to
find the answer in there.

Incidently, I found the National code on the web at this location:
http://phcc.files.cms-plus.com/Depts/Technical/2006NSPCNonIllustratedWeb.pdf

Thanks for any information you can provide:

Best, John

Special 468x60
Posted by Wayne Whitney on June 17, 2008, 1:07 pm

> In the interest of planning the job, I'm wondering, Can a Toilet, (as
> part of a bath, including shower and lavatory, or half bath including
> only lavatory), be attached to a Horizontal branch of a waste stack?
> I've only ever seen them attached to the vertical sections of the
> stack. If so, what restrictions are there on the length of the
> Horizontal branch.

My understanding is that they are fine on a horizontal branch of
appropriate size, as long as you have a vent take off sufficiently
close to the closet bend.

Cheers, Wayne

Posted by Colbyt on June 17, 2008, 2:35 pm

> Hello Group,
>
> I'm working for a friend on a gut job rehab, and his architect seems
> inclined to provide plans with no mechanical details and no place to
> put waste stacks.
>
> In the interest of planning the job, I'm wondering, Can a Toilet, (as
> part of a bath, including shower and lavatory, or half bath including
> only lavatory), be attached to a Horizontal branch of a waste stack?
> I've only ever seen them attached to the vertical sections of the
> stack. If so, what restrictions are there on the length of the
> Horizontal branch.
>
> I've been reading the 2006 National Plumbing Code, and I can't seem to
> find the answer in there.
>
> Incidently, I found the National code on the web at this location:
> http://phcc.files.cms-plus.com/Depts/Technical/2006NSPCNonIllustratedWeb.pdf
>
> Thanks for any information you can provide:
>
> Best, John

I agree with Wayne.

You need to have a vent within 3 feet of the WC (may be less where you are).
and the other fixtures all need to tie into the vent. They the actual sewage
can flow in graded pipes wherever it needs to go. My downstairs half bath
and washer discharge into the same 4" pipe and run a good 20-25 feet, take a
45 degree to the floor before they enter the sewer under the basement floor.

Colbyt



Similar ThreadsPosted
USA Plumbing code: Maximum distance from a dry vent? July 5, 2008, 7:05 am
Toilet-to-wall distance August 3, 2008, 3:14 pm
Slow flushing toilet: Vent stack? January 29, 2006, 3:14 pm
Vertical Blinds or Drapes? July 25, 2005, 3:03 am
Best fitting for jog in vertical DWV pipe March 11, 2006, 3:31 pm
Vertical vs. Horizontal Blinds May 18, 2006, 10:46 am
Vertical EMT Coupling and Support. June 19, 2006, 8:56 am
Cutting down vertical blinds..... July 5, 2006, 2:39 pm
Vertical Ceiling Tiles January 24, 2007, 7:43 pm
vertical blinds connector ? July 15, 2008, 12:10 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap