Need advise on install of roof vent fan Keith Boeheim 05-23-2007
If you were  Registered and logged in, you could reply and use other advanced thread options
Posted by Keith Boeheim on May 23, 2007, 3:37 pm
I have a 7 y/o single story home with a hip roof in Western New York. I
would like to have a powered roof mounted fan with thermostat and
humidistat to regulate temp and humidity in the crawl space. I have a
ridge vent (short in length because of the hip) and soffit vents. Roof
trusses are 24" oc and the soffit vents are every other space with foam
baffles. Local home repair show on radio Saturday mornings says that an
HVAC contractor is the trade to install the unit. Is this correct? Also,
if the fan is mounted high on the roof will it draw from the ridge
vent and not the soffits and if this is a problem should it be mounted
midway up the roof or do I have to remove the ridge vent?

Thanks for any advise

kb

Posted by on May 23, 2007, 7:38 pm
we put the fans so the top of fan is just lower than the top of the
peak, center of roof. get a fan next step bigger than your sq ft calls
for and youll be aok with the ridge vent.

http://www.minibite.com/america/malone.htm


Posted by DK on May 24, 2007, 7:44 am
On Wed, 23 May 2007 15:37:51 -0400, Keith Boeheim

>I have a 7 y/o single story home with a hip roof in Western New York. I
>would like to have a powered roof mounted fan with thermostat and
>humidistat to regulate temp and humidity in the crawl space. I have a
>ridge vent (short in length because of the hip) and soffit vents. Roof
>trusses are 24" oc and the soffit vents are every other space with foam
>baffles. Local home repair show on radio Saturday mornings says that an
>HVAC contractor is the trade to install the unit. Is this correct? Also,
> if the fan is mounted high on the roof will it draw from the ridge
>vent and not the soffits and if this is a problem should it be mounted
>midway up the roof or do I have to remove the ridge vent?
>
>Thanks for any advise
>
>kb

crawl space is under the floor. attic is above the ceiling. What
are you talking about crawl space for? Were you doing drugs when
you wrote that?

humidity and temperature can NOT be regulated if you don't have a
closed system.

You don't give a damn where the powered roof vent sucks air from. It
will remove more hot air from your attic than ridge vents alone. Do
NOT remove the ridge vents. For small hip peaks, you can put ridge
vents down the slopes.



Posted by on May 24, 2007, 11:38 am
> On Wed, 23 May 2007 15:37:51 -0400, Keith Boeheim
>
> >I have a 7 y/o single story home with a hip roof in Western New York. I
> >would like to have a powered roof mounted fan with thermostat and
> >humidistat to regulate temp and humidity in the crawl space. I have a
> >ridge vent (short in length because of the hip) and soffit vents. Roof
> >trusses are 24" oc and the soffit vents are every other space with foam
> >baffles. Local home repair show on radio Saturday mornings says that an
> >HVAC contractor is the trade to install the unit. Is this correct? Also,
> > if the fan is mounted high on the roof will it draw from the ridge
> >vent and not the soffits and if this is a problem should it be mounted
> >midway up the roof or do I have to remove the ridge vent?
>
> >Thanks for any advise
>
> >kb
>
> crawl space is under the floor. attic is above the ceiling. What
> are you talking about crawl space for? Were you doing drugs when
> you wrote that?
>
> humidity and temperature can NOT be regulated if you don't have a
> closed system.
>
> You don't give a damn where the powered roof vent sucks air from. It
> will remove more hot air from your attic than ridge vents alone. Do
> NOT remove the ridge vents. For small hip peaks, you can put ridge
> vents down the slopes.

So you think you'll get the same amount of cooling when a powered
attic fan is pulling air from a vent that is 2 ft aways and then
sending it right back out, as opposed to pulling it up from the soffit
vents? In this case, I would locate it in an area away from the ridge
vent.

I'd be curious as to what temp and humidity problems the OP is trying
to solve. With a ridge vent and soffit vents, there should be no
humidity problem, unless there is a source for humidity entering the
attic. If that's the case, I'd focus on that first. If the attic
is still getting extremely hot with the existing venting, then a
powered fan might be in order. But, I'd want to measure how hot it's
getting first. And I'd also want to make sure the soffit vents are
open. It's common for the insulation to be installed so that it
blocks them.




Posted by DK on May 25, 2007, 8:43 am
On 24 May 2007 08:38:54 -0700, trader4@optonline.net wrote:

>> On Wed, 23 May 2007 15:37:51 -0400, Keith Boeheim
>>
>> >I have a 7 y/o single story home with a hip roof in Western New York. I
>> >would like to have a powered roof mounted fan with thermostat and
>> >humidistat to regulate temp and humidity in the crawl space. I have a
>> >ridge vent (short in length because of the hip) and soffit vents. Roof
>> >trusses are 24" oc and the soffit vents are every other space with foam
>> >baffles. Local home repair show on radio Saturday mornings says that an
>> >HVAC contractor is the trade to install the unit. Is this correct? Also,
>> > if the fan is mounted high on the roof will it draw from the ridge
>> >vent and not the soffits and if this is a problem should it be mounted
>> >midway up the roof or do I have to remove the ridge vent?
>>
>> >Thanks for any advise
>>
>> >kb
>>
>> crawl space is under the floor. attic is above the ceiling. What
>> are you talking about crawl space for? Were you doing drugs when
>> you wrote that?
>>
>> humidity and temperature can NOT be regulated if you don't have a
>> closed system.
>>
>> You don't give a damn where the powered roof vent sucks air from. It
>> will remove more hot air from your attic than ridge vents alone. Do
>> NOT remove the ridge vents. For small hip peaks, you can put ridge
>> vents down the slopes.
>
>So you think you'll get the same amount of cooling when a powered
>attic fan is pulling air from a vent that is 2 ft aways and then
>sending it right back out, as opposed to pulling it up from the soffit
>vents? In this case, I would locate it in an area away from the ridge
>vent.
>
>I'd be curious as to what temp and humidity problems the OP is trying
>to solve. With a ridge vent and soffit vents, there should be no
>humidity problem, unless there is a source for humidity entering the
>attic. If that's the case, I'd focus on that first. If the attic
>is still getting extremely hot with the existing venting, then a
>powered fan might be in order. But, I'd want to measure how hot it's
>getting first. And I'd also want to make sure the soffit vents are
>open. It's common for the insulation to be installed so that it
>blocks them.
>
>

I set my power vent fan to come on at 105. That occurs on any sunny
day when temp reaches 90 degrees. That means that my ridge vents are
not moving enouigh air to make up for all the heat from the sun on the
shingles.

The net result is that my attic now reaches a maximum temp of about
110 instead of the 125 before I installed the power vent fan.

The power fan shuts off about sunset on a clear day.






Similar ThreadsPosted
Central Air Condo Install, Please advise February 22, 2006, 1:06 pm
Range hood vent options/ self venting or vent through roof ? September 2, 2007, 10:35 am
Temporary roof repair after Wilma advise October 30, 2005, 11:46 am
Roof framing repair advise needed June 13, 2007, 11:23 pm
roof vent, ridge vent or what? May 17, 2006, 1:56 pm
soffit vent - install from above or below ?? September 1, 2006, 1:03 pm
dryer vent install August 22, 2008, 8:23 am
Takagi direct vent install July 14, 2006, 12:28 pm
How do I install a sump radon vent system October 17, 2005, 6:00 pm
Vent that does not need to go thru the roof? August 21, 2005, 3:49 am

Contact Us | Privacy Policy

XML SitemapXML Sitemap